5 Module description

a Left LED (green/red)
b Right LED (green/red)
LED displays
Initialisation
Left LED (green) and right LED (red)
flash alternately
Teach-in
Left LED (red) is lit
All LEDs off
Right LED (green) gives three long flashes
Right LED (red) gives three short flashes
Left LED (red) and right LED (green) flash
rapidly and simultaneously
Right LED (green) gives five long flashes
Right LED (red) lights up for approx. 1 second
Delete mode (via the address switch)
Left LED (red) and right LED (green) are lit
continuously and simultaneously
Delete user fingerprints (in operation)
Left LED (red) and right LED (green)
flash rapidly and simultaneously
Left LED (red) and right LED (green) are lit
continuously and simultaneously

Normal operation

Left LED (green) is lit
All LEDs off
Right LED (green) gives five long flashes
Right LED (red) flashes rapidly five times
Left LED (red) flashes rapidly
Error
Left LED (red) and right LED (red) flash
10
Meaning
Power was applied and the device is being initialised
Module is ready for fingerprint read-in
Fingerprint recognition is being processed
Fingerprint has been recognized
Fingerprint has not been recognized
Inadequate image of the fingerprint.
Repeat teach-in process.
Teach-in process completed successfully
The teach-in process was not successful and is being aborted
(timeout, fingerprint already recognised, different fingerprint used,
etc.)
Delete mode is active – as delivered status is being established
Delete mode can be activated for all user fingerprints
Delete mode is active – all user fingerprints or the user fingerprints
for a group are being deleted
Normal operating state: The device is ready for operation and rec-
ognises at least one fingerprint
Fingerprint recognition is being processed
Fingerprint recognised: Access
Fingerprint not recognised: No access
FPM is blocked as an unauthorized fingerprint has been scanned
several times in succession. The block can be lifted (operating state)
by scanning an authorized fingerprint twice. The block is automati-
cally lifted after 1 minute.
General error message