INSTALLATION
INSTALLATION
Thread the pump into the top of the casing of a driven well
or bolt it to the cover of a dug well.
NOTE: The base of the pump comes ready for use with a
1-1/4" pipe or it can be reduced with a bushing for use with a
1" pipe. Be certain there is a drop pipe extending down into
the well water from the pitcher pump. The cap is adjustable
for a wide range of handle positions.
Sealing Pipe Joints
Use only Teflon tape or Teflon based joint compounds
for making all threaded connections to the pump
itself. Make sure that all pipe joints in the suction pipe
are both air and water tight. If the suction pipe can
suck air, the pump will not be able to pull water from
the well.
Priming the Pump
Never operate pump dry. Operating the pump
without water may cause damage to the cup leather.
ALWAYS fill pump with water before starting to pump.
NOTICE The pump may need to be primed more than once
before you can lift water. For best operation a foot valve
should be installed at the bottom of the suction line.
Figure 1
P20-19 (01-17-20)
3351 1198 NF
The pitcher pump must be primed before lifting water
(Figure 1). Pour water in the top of the pitcher pump until it
runs out of the spout. Wait 5 minutes until the cup leather
swells enough to make contact with the pump wall. If nec-
essary, add more water.
MAINTENANCE
Replacing the Cup Leather
(Refer to the Exploded View, Page 4 for Key numbers)
Step 1. Loosen the capscrew on the pump cap (Key No. 2)
and lift the plunger assembly out of the pump.
Step 2. Unscrew the cup leather holder (Key No. 7).
Step 3. Remove old cup leather (Key No. 6), and put on new
cup leather.
Step 4. Screw leather cup holder back into original
position.
Step 5. Reinstall plunger assembly and cap (Key Nos. 1
through 7).
Step 6. Insert capscrew and tighten.
Replacing the Valve Leather
(Refer to the Exploded View, Page 4 for Key numbers)
Step 1. Remove one of the capscrews located at the base
of the plunger body and loosen the other capscrew.
Step 2. Remove the pump body (Key No. 8) from the pump
base (Key No. 11).
Step 3. Remove the check valve (Key No. 9) from the valve
leather (Key No. 10).
Step 4. Remove old valve leather. Clean any old leather off
of column and base.
Step 5. Position the raised end of check valve at the
attached/hinged end of valve leather.
Step 6. Reattach check valve to the valve leather with the
screw, nut and washer.
Step 7. Position new valve leather with check valve on
base.
Step 8. Reattach pump body to the base by reinstalling and
tightening the capscrews, washers, and nuts.