Troubleshooting (cont.)
Symptoms
5. Waterfall lights do not work.
6. Unit stops automatically before
18 minutes.
7. Unit does not stop
automatically after 22 minutes.
8. Noisy operation.
9. Remote does not work.
Kohler Co.
Probable Causes
B. Waterfall wiring
loose/damaged or butterfly
valve is faulty.
C. Not enough water in footbath
basin (pump cavitates).
D. Keypad does not work.
E. Control does not work.
A. Loose or damaged wiring.
B. Power supply for lighting does
not work.
A. GFCI or ELCB has tripped.
B. Motor overheated and
protection device activated.
A. Timer mechanism accidentally
deactivated.
A. Not enough water in footbath
basin.
B. Band straps (if applicable) on
the pump are not cut.
A. Remote not programmed.
11
Recommended Action
B. Identify source of fault and
correct or replace wiring or
butterfly valve. Refer to
installer/dealer.
C. Fill basin 3" (7.6cm) over top of
suction cover.
D. Replace keypad. Refer to
installer/dealer.
E. Replace control. Refer to
installer/dealer.
A. Identify source and correct.
Refer to installer/dealer.
B. Replace lighting supply box in
tower. Refer to installer/dealer.
A. Set/Reset GFCI or ELCB.
B. Check for restricted air space
around pump box, motor vent
blockage, suction/harness
blockage. Correct and allow
motor to cool.
A. See service manual. Refer to
installer/dealer.
A. Fill basin 3" (7.6cm) over top of
suction cover.
B. Cut band straps.
A. Re-program remote following
instructions.