Tripp-Lite SmartOnline SUINT1000LCD2U Manual De Instrucciones página 14

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Operations
Front Panel LCD Selection and Configuration Options
MAIN MENU / SUBMENU
STATUS
Load Status
In/Out Status
Energy Status
Int. Batt. Status
Ext. BP . Status
Power Flow Chart
CONTROL
Start Batt. Test
Reset Batt. Age
Reset Fault State
Auto Batt. Testing
EVENT LOG
On Batt. Events
All Events
Reset Batt. Events
Reset All Events
SETTINGS
Basic setup
DISPLAY / SETTING OPTIONS
• Load level (%, kW, kVA, A, PF)
• Available capacity (%, kW, kVA)
• Input voltage & frequency (Vac, Hz)
• Output voltage & frequency (Vac, Hz)
• Load Group1 (On, Off)
• Load Group2 (On, Off)
• Efficiency (%)
• Avg. Power (kw/hr.)
• Configured power strategy
• Installed (mm/dd/yyyy)
• Expires (mm/dd/yyyy)
• Battery pack model & serial number
• Installed (mm/dd/yyyy)
• Expires (mm/dd/yyyy)
• View UPS operational flow chart
• Initiates a manual battery test
• Resets the battery age
• Resets any fault state messages
• Set regular battery self-test interval
o Disable
o 4 weeks (factory setting)
o 13 weeks
o 26 weeks
• Event counter
(UPS On-battery events only)
• Total minutes (total minutes of
on-battery mode operation)
• Most recent power failure (date)
• Days until battery replacement alert
(days)
• Event details (date, time &
description for the last 20 logged events)
• Event counter (all events)
• Most recent event (date)
• Date time log
• Event details (date, time and description
of each logged event)
• Resets battery events only
• Resets all events
System
• Current date (display, set date)
• Current time (display, set time)
• Audible alarm (enable, disable)
• Language (select)
Output voltage
• 200
• 208
• 220
• 230
• 240
DISPLAY / SETTING DESCRIPTION
UPS load percent (%), kilowatt (kW), kilovoltamp
(kVA), amp (A) & power factor (PF).
UPS capacity available in percent (%), kilowatts (kW)
& kilovoltamps (kVA).
Displays UPS input and output status information for input /
output voltage (Vac), frequency (Hz) and outlet group power
status (On/Off) information.
Displays UPS efficiency percentage (%), connected equipment
kilowatt hour consumption (kw/hr.) and configured power
strategy.
Displays internal Replacement Battery Cartridge install date and
user configured expiration date.
Displays external Battery Pack model number & serial number
(Tripp Lite SMART BATTERY PACKS) only, installation date and
user configured expiration date.
Displays UPS operating mode in a graphical flow chart.
Initiates a momentary UPS battery self-test with immediate
Pass/Fail results.
Resets battery age to today's date. Use this option after NON-
SMART battery replacement.
Use this option to clear UPS fault messages.
Use this option to initiate automatic UPS battery testing at
regular intervals.
Displays a summary of all ON-BATTERY events where the UPS
switched to battery mode in response to a protected condition.
Event details lists the last 20 battery events. As additional alerts
occur, the oldest records will be automatically removed.
Displays a summary of all Recorded events. Event details lists
the last 20 events. As additional alerts occur, the oldest records
will be automatically removed.
Resets all data in the on-battery events screen set.
Resets all data in the all-events screen set.
Displays, sets and resets date, time, audible alarm status and
language settings.
Note: Audible Alarm DISABLE setting prevents power fail and
operating fault alarms only, the UPS will always "beep" to
confirm the UPS is accepting user input from the front-panel
LCD navigation buttons.
Use the SETTINGS / BASIC / OUTPUT VOLTAGE option to display
or set the nominal UPS output voltage (changes take effect on
next restart).
14
Tabla de contenido
loading

Tabla de contenido