Special Functions - Lowara ResiBoost MMW Manual De Instalación, Funcionamiento Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90
Table 20: Models MMA and MTA
Parame-
Descrip-
Range
ter
tion
Pr
Propor-
2 to 100
tional co-
efficient
of the
PID reg-
ulator (*)
ACCEL-
Acceler-
2 to 15
ER.
ation
time.
Minimum
time re-
quired
for the
frequen-
cy of the
motor to
go from
minimum
to maxi-
mum fre-
quency.
DECEL-
Deceler-
2 to 15
ER.
ation
time.
Minimum
time re-
quired
for the
frequen-
cy of the
motor to
go from
minimum
to maxi-
mum fre-
quency.
FREQ.S
Selection
4 / 8
W.
of the
switching
frequen-
cy of the
power
mod-
ule.**
DE-
Select
NO/YES -
FAULT
YES to
PAR
set the
default
values
RESET
Select
NO/YES -
CONT.
YES to
reset the
operation
counters
and the
alarm
log.
SET
Set the
0.5 to 10
PRESS
required
0.0 to 16
Unit of
Default
meas-
urement
-
19
Hz/sec
10
Hz/sec
10
kHz
8
NO
NO
bar
2.5
Parame-
Descrip-
Range
ter
tion
pressure
(in rela-
value of
tion to
the sys-
the full
tem (set
scale of
point)
the sen-
sor)
MIN.PRE
Pressure
0.0 to
SS
value of
(SET
the sys-
PRESS
tem be-
-0.4)
low
0.0 =
which
Disabled
the A4
"mini-
mum
pres-
sure"
alarm is
trig-
gered.
When
the alarm
is trig-
gered,
the pump
stops
and the
ART
function
is ena-
bled.
See
Spe-
cial func-
tions.
Trigger-
ing of the
alarm is
delayed
by the
length of
time set
in the
MP DE-
LAY pa-
rameter.
(*) these values depend on the type of installation
and are compatible with all the various types of sys-
tem.
(**) The noise level of the motor can be reduced us-
ing a frequency of 8 kHz. Increasing the switching
frequency reduces the capacity of the converter. It is
advisable to use a frequency of 4 kHz when the mo-
tor cable is long, in order to minimize the capacitive
currents in the cable.
WARNING:
Editing the parameters can cause the
converter to malfunction. Contact the as-
sistance service when modifications are
required.

5.4 Special functions

en - Original instructions
Unit of
Default
meas-
urement
bar
0.0
37