Pump Specifications; Electrical Requirements; Mechanical Installation - Lowara ResiBoost MMW Manual De Instalación, Funcionamiento Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 90
Output frequen-
cy
Rated input cur-
6,3A
rent
(Uin-230V)
Rated output
6A
6
current
(Uout=230V)
Overcurrent
20%, 10 second maximum
Recommended
13A
7
line protection
Consumption in
standby
Type of load
Nominal cosφ
≥0,60
(motor)
IP protection
Maximum power
cable section
Maximum motor
power cable
section
Set-point pres-
0,5 to 16 bar (50 to 1600 kPa)
sure
Ambient tem-
0 to 40°C (32 to 104°F)
perature
Ambient humidi-
< 50%, non-condensing
ty
8
Elevation
Protection fuse
10A
(inside)
Cooling
Natural
air
Auxiliary power
supply of pres-
sure sensor
Digital input for
float switch con-
tact
Dimensions and
weight

3.4 Pump specifications

Refer to the user and maintenance manual of the
electric pump. It is essential to consider the limita-
tions of use of the converter together with those of
the electric pump. See
Technical
is responsible for checking the limitations of the
electric pump if they are not specified in this manual.
4 Installation
Precautions
15-50 Hz
12,6A
11A
18A
12A
6A
10A
16A
16A
25A
4W
electric motor
≥0,75
54
2
2,5mm
2
2,5mm
≤2000m asl
16A
16A
20A
Forced
Natural
Forced
air
air
air
15Vdc
24Vdc, 23,9mA
See
Figure 5
.
data. The customer
WARNING:
• Observe accident prevention regula-
tions in force.
• Use suitable equipment and protec-
tion.
• Always refer to the local and/or na-
tional regulations, legislation, and co-
des in force regarding the selection of
the installation site, plumbing, and
power connections.

4.1 Electrical requirements

• The local regulations in force overrule specified
requirements listed below.
Electrical connection checklist
Check that the following requirements are met:
• The electrical leads are protected from high tem-
perature, vibrations, and collisions.
• The current type and voltage of mains connec-
tion must correspond to the specifications on the
data plate on the pump.
• It is suggested to supply power to the converter
with a dedicated power line and it is provided
with:
• A high-sensitivity differential switch (30 mA)
[residual current device RCD] suitable for
earth fault currents with pulsating content. In-
terrupter must be marked with the following
symbol:
ELCB
(GFCI)
Refer to
Figure 11
andFigure 12
for models MMA, MTA.
• A mains isolator switch with a contact gap of
at least 3 mm
The electrical control panel checklist
NOTICE:
The electrical panel must be compatible with the da-
ta of the electric pump powered by the converter. In-
appropriate combinations do not guarantee the pro-
tection of the unit.
Check that the following requirements are met:
• The control panel must protect the converter and
the pump against short circuit. A time lag fuse or
a circuit breaker (Type C model is suggested)
can be used to protect the pump.
• The converter must be programmed correctly to
protect the pump from overloading. Refer to
Start-up and programming
• A time lag fuse which is inside the converter pro-
tects the pump against short circuits. Refer to
Figure 12
and
Figure 14
The motor checklist
Use cable according to rules with 3 leads (2 + earth/
ground) or 4 leads (3 + earth/ground). All cable must
be heat-resistant up to a minimum of +85°C (185°F).

4.2 Mechanical installation

NOTICE:
en - Original instructions
for models MMW, MTW
for programming.
.
27
Tabla de contenido
loading

Este manual también es adecuado para:

Resiboost mtwResiboost mmaResiboost mta

Tabla de contenido