Kenmore 415.23665310 Manual De Uso página 29

Parrilla a gas de propane liquido
Ocultar thumbs Ver también para 415.23665310:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

EMERGENCIES: if a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.
iJib,
Gas leaking
from
cracked/cut/burned
hose.
Gas leaking
from
LP
cylinder.
Gas leaking
from
LP
cylinder
valve.
Gas leaking
between
LP cylinder
and
regulator
connection.
Fire coming
through
control
panel.
Grease
fire or
continuous
excessive
flames
above
cooking
surface.
• Damaged
hose.
• Mechanical
failure
due to rusting or
mishandling.
• Failure
of cylinder
valve from
mishandling
or mechanical
failure.
• Improper installation, connection not
tight, failure of rubber seal.
• Fire in burner
tube section
of burner
due to blockage.
• Too much grease
buildup
in burner
area.
• Turn off gas at LP cylinder
or at source on natural
gas systems.
If the hose is cracked
or cut but not burned,
simply replace
valve!hose!
regulator.
If the hose is burned,
the cause could be
other than a faulty
valve!hose!regulator.
Discontinue
use of grill
until a plumber
or gas technician
has investigated
and
corrected
the problem.
• Replace
LP cylinder.
• Turn off LP cylinder
valve. Return LP cylinder
to gas supplier.
• Turn off LP cylinder
valve. Remove
regulator
from cylinder
and
visually
inspect
rubber
seal for damage.
See LP Cylinder
Leak
Test and Connecting
Regulator
to the LP Cylinder.
• Turn off control
knobs and LP cylinder
valve.
Leave lid open to
allow
flames
to die down. After fire is out and grill is cold,
remove
burner
and inspect
for spider
nests or rust. See Spider
Alert and Cleaning
the Burner Assembly
sections of this Use &
Care Guide.
• Turn off control
knobs and LP cylinder
valve.
Leave lid open to
allow
flames
to die down. After cooling,
clean
food
particles
and excess grease
from
inside firebox
area, grease
tray, and
other surfaces.
Burner(s) will not
light
using ignitor.
(See Electronic
Ignition
Troubleshooting
also)
Continued on next
page.
GAS ISSUES:
• Trying to light wrong
burner.
• Burner not engaged
with
control
valve.
• Obstruction
in burner.
• No gas flow.
• Vapor lock at coupling nut to LP
cylinder.
• Coupling
nut and LP cylinder
valve not
fully connected.
ELECTRICAL
ISSUES:
" Electrode
cracked
or broken;
"sparks
at
crack."
• Electrode
tip not in proper
position.
• Wire
and!or
electrode
covered
with
cooking
residue.
• Wires
are loose or disconnected.
• Wires are shorting (sparking) between
ignitor and electrode.
• Dead
battery.
• See instructions on control
panel and in Use and Care section.
• Make sure valves are positioned
inside of burner
tubes.
• Ensure burner
tubes are not obstructed
with
spider webs or other
matter.
See cleaning
section
of Use and Care.
• Make sure LP cylinder
is not empty.
If LP cylinder
is not empty,
refer to "Sudden
drop in gas flow."
• Turn off knobs and disconnect
coupling
nut from LP cylinder.
Reconnect
and retry.
• Turn the coupling
nut approximately
one-half
to three-quarters
additional
turn until solid stop. Tighten
by hand only - do not
use tools.
• Replace
electrode(s).
Main
Burners:
• Tip of electrode
should
be pointing
toward
gas port opening
on
burner.
The distance
should
be 1/8"
to t/4".
Adjust
if necessary.
Side burner:
• Tip of electrode
should
be pointing
toward
gas port opening
on
burner, the distance
should
be 1/8"
to 3/16".
Adjust
if necessary.
• Clean wire and!or
electrode
with
rubbing
alcohol
and clean
swa b.
• Reconnect
wires or replace
electrode!wire
assembly.
• Replace
ignitor
wire!electrode
assembly.
• Replace with a new AA-size
alkaline
battery.
464225913"
29
Tabla de contenido
loading

Tabla de contenido