Módulos de avance (VS)
1.2 Ajustes del regulador de intensidad
Tabla 1-9
Tabla de adaptación para módulo de potencia 6SN112V–1AA00–0FA1 100/200 A
Servomotor
M [Nm]
[Nm]
1FT
1FT
M
o
4101–VSK71
20,0
4101–VSN71
20,0
4102–VSG71
33,0
4102–VSK71
33,0
4104–VSG71
45,0
4104–VSK71
45,0
4106–VSG71
59,0
5066–VAK71
6,5
5072–VAG71
10,0
5072–VAK71
10,0
5073–VAK71
7,0
5074–VAF71
14,0
5074–VAG71
14,0
5074–VAK71
14,0
5074–VSG71
16,0
5074–VSK71
16,0
5076–VAC71
18,0
5076–VAF71
18,0
5076–VAG71
18,0
5076–VAK71
18,0
5076–VSG71
20,5
5076–VSK71
20,5
5100–VAF71
10,0
5100–VAG71
10,0
5100–VAK71
10,0
5101–VAC71
15,0
5101–VAF71
15,0
5101–VAG71
15,0
5101–VAK71
15,0
5102–VAA71
27,0
5102–VAC71
27,0
5102–VAF71
27,0
5102–VAG71
27,0
5102–VSF71
34,0
5102–VSG71
34,0
5103–VAC71
19,0
5103–VAF71
19,0
5103–VAG71
19,0
5104–VAA71
37,0
5104–VAC71
37,0
5104–VAF71
37,0
5104–VSF71
48,0
5106–VAA71
45,0
5106–VAC71
45,0
5106–VAF71
45,0
5106–VSF71
57,0
Definición:
1) El valor indicado es la intensidad máxima permitida de la combinación parte de potencia/motor respectiva. Depen-
diendo de los órganos mecánicos accionados puede ser necesaria una reducción del valor indicado.
VS/1-14
SIMODRIVE 611 Sistema analógico Instrucciones de puesta en marcha (IAA) – Edición 10.00
I [Α]
[Α]
[r/min]
[r/min]
I
n
n
o
nom
2
33,0
6000
o
39,0
8000
x
35,0
4000
x
47,0
6000
o
46,0
4000
o
60,0
6000
o
56,0
4000
o
11,6
6000
o
12,0
4000
o
17,5
6000
o
12,5
6000
o
13,0
3000
o
16,5
4000
o
25,0
6000
o
19,0
4000
o
28,0
6000
o
11,5
2000
o
16,5
3000
x
21,5
4000
o
32,0
6000
o
24,5
4000
o
36,0
6000
o
9,2
3000
x
12,5
4000
o
18,0
6000
x
9,4
2000
x
14,5
3000
o
17,5
4000
x
26,5
6000
o
9,9
1200
x
16,5
2000
x
25,0
3000
o
31,5
4000
o
31,5
3000
x
39,5
4000
o
12,0
2000
o
17,5
3000
x
23,0
4000
x
14,0
1200
o
22,5
2000
o
34,0
3000
o
44,0
3000
o
17,0
1200
x
26,8
2000
x
42,5
3000
o
54,0
3000
o
o = Interruptor en posición base OFF
x = Interruptor en posición ON
1)
Límite de intensidad
Interruptores
[Α]
[Α]
I
I
máx
á
3
4
5
x
o
o
136,0
o
o
o
170,0
o
o
o
170,0
o
o
o
200,0
o
o
o
200,0
o
o
o
200,0
o
o
o
200,0
x
o
x
60,0
x
o
x
60,0
x
x
o
82,0
x
o
x
60,0
x
o
x
60,0
x
x
o
82,0
o
x
o
100,0
x
x
o
82,0
o
x
o
100,0
o
x
x
52,0
x
x
o
78,0
o
x
o
100,0
x
o
o
136,0
o
x
o
100,0
x
o
o
136,0
x
x
x
46,0
x
o
x
60,0
o
x
o
92,0
x
x
x
46,0
x
o
x
60,0
o
x
o
92,0
x
o
o
136,0
x
x
x
46,0
x
x
o
78,0
o
x
o
100,0
x
o
o
136,0
x
o
o
122,0
x
o
o
136,0
x
o
x
60,0
o
x
o
92,0
x
o
o
122,0
x
o
x
60,0
o
x
o
100,0
x
o
o
136,0
x
o
o
136,0
x
x
o
78,0
x
o
o
122,0
o
o
o
200,0
o
o
o
200,0
Siemens AG 2000 All Rights reserved
10.00
10.00
Ganancia regulador de
intensidad
Interruptores
Kp(I)
Kp(I)
6
7
8
9
x
x
o
o
2,5
x
x
o
o
2,0
o
o
x
x
9,5
o
x
x
o
5,5
x
o
o
x
6,5
x
x
o
o
2,5
o
x
x
o
5,5
x
o
x
o
4,5
x
x
o
x
8,0
o
x
x
o
5,5
o
o
x
o
4,0
x
x
o
x
8,0
x
o
o
x
6,5
x
x
o
o
2,5
o
o
o
x
6,0
x
x
o
o
2,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
x
o
o
2,5
x
o
x
o
4,5
x
x
o
o
2,5
x
x
o
x
8,0
o
o
o
x
6,0
x
o
x
o
4,5
o
o
x
x
9,5
o
o
o
x
6,0
o
o
o
x
6,0
o
o
x
o
4,0
x
x
x
x
11,5
o
o
x
x
9,5
x
o
x
o
4,5
x
o
x
o
4,5
o
x
x
o
5,5
o
o
x
o
4,0
o
o
x
x
9,5
x
o
o
x
6,5
o
x
x
o
5,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
o
x
o
4,5
x
x
x
x
11,5
x
x
o
x
8,0
o
x
x
o
5,5
x
o
x
o
4,5