Technical Characteristics - Comelit 20004607 Manual Tecnico

Módulo bus genérico 2 entradas/2 salidas
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Warning
• This Comelit product was designed for use in the creation of security and home automation systems in residential, commercial or industrial settings
and in public buildings or buildings used by the public.
• All activities connected to the installation of Comelit products must be carried out by qualified technical personnel, with careful observation of the
indications provided in the manuals / instruction sheets supplied with those products.
• Use wires with a cross-section suited to the distances involved, observing the instructions provided in the system manual.
• We advise against running the system wires through the same duct as the power cables (230V or higher).
• Cut off the power supply before carrying out any maintenance procedures.
• To ensure Comelit products are used safely: carefully observe the indications provided in the manuals / instruction sheets and make sure the system
created using Comelit products has not been tampered with / damaged.
• Comelit products do not require maintenance aside from routine cleaning, which should be carried out in accordance with the indications provided in
the manuals / instruction sheets. Any repair work must be carried out: for the products themselves, exclusively by Comelit Group S.p.A., for systems,
by qualified technical personnel.
• Comelit Group S.p.A. does not assume any responsibility for: any usage other than the intended use; non-observance of the indications and warnings
contained in this manual / instruction sheet. Comelit Group S.p.A. nonetheless reserves the right to change the information provided in this manual /
instruction sheet at any time and without prior notice.
ART. 20004607
Home automation module equipped with 2 inputs for the direct connection of 2 control buttons and 2 outputs with 2A solid state
relays allowing control of loads up to 240 VAC and a maximum of 500 W.
Suitable for control of halogen, LED and compact fluorescent lights.

TECHNICAL CHARACTERISTICS

Power supply voltage
Consumption
Inputs
Outputs
TOTAL MAXIMUM LOAD: 2A - 240 VAC
240 VAC halogen lamps
240 VAC compact fluorescent lamps (CFL)
240 VAC LED lamps
BUS and power supply
Positioning
Approvals
Operating temperature
Storage temperature
Relative air humidity
Weight
Dimensions
* with access allowed only for support or servicing by qualified personnel.
ADDRESSING
The address of the module on the home automation BUS must be set using the DIP-switches on the module itself. The table at page
8 can be used to identify the DIP-switch settings corresponding to the address you wish to set.
If the DIP-switches are altered, the power supply must be cut off and reactivated for the new address to be set on the
module.
PROGRAMMING
SimpleProg software is required to program Comelit home automation devices; this software can be downloaded from the website
pro.comelitgroup.com
Programming must be carried out by connecting the device to the BUS and sending the programming over this.
• The module address cannot be changed via SimpleProg.
• Specifications are subject to change without notice.
O1 + O2 = MAX 500W
24 VDC ±5%
between 8,5 and 16 mA
I1
input 1
V+
24 v
I2
input 2
C
common
O1
output 1
O2
output 2
D
data BUS
+
+24 VDC power supply
-
Power supply negative
On a DIN rail on a dedicated control panel or in a
junction box*
CE
0° to 40°C Indoor use
-10° to +70°C
5 to 95% with no condensation
40 g
50 x 50 x 18.5 mm (1 DIN module)
3
Tabla de contenido
loading