RAGGIO C
Code Description
DHW user max. set-
P46
point
DHW pump Post-Cir-
P47
culation
Max. output in DHW
P48
Not implemented
P49
Not implemented
P50
Solar off temperature
P51
Solar on temperature
P52
Solar standby time
P53
Heating deltaT adjust-
P54
ment temperature
Primary exchanger
P55
protection temperature
System min. pressure
P56
value
System nominal pres-
P57
sure value
Exchanger protection
P58
intervention (b01=3)
Heating hysteresis
P59
after ignition
Timer for heating hys-
P60
teresis after ignition
Pump deactivation
P61
with OpenTherm
System filling mode
P62
Notes:
1. Parameters with more than one description vary their function and/or range in relation to the
setting of the parameter given in brackets.
2. Parameters with more than one description are reset to the default value if the parameter given
in brackets is modified.
3. The Maximum Heating Power parameter can also be modified in Test Mode.
To return to the service menu, simply touch the "arrow" icon
Combustion Control Menu
ONLY QUALIFIED PERSONNEL CAN ACCESS THE MENU AND MODIFY THE RELEVANT
PARAMETERS.
Code
Description
Gas type selection
Sc01
Ignition gas setting
Sc02
Ignition power
Sc03
EN
Range
40 ÷ 70°C
0 ÷ 255 seconds
0 ÷ 100%
--
--
0 ÷ 100°C
0 ÷ 100°C
0 ÷ 255 seconds
0 ÷ 60°C
0 ÷ 150°C
0 ÷ 8bar/10
5 ÷ 20bar/10
0 = No F43
1 ÷ 15 = 1 ÷ 15°C/second
6 ÷ 30°C
60 ÷ 180 seconds
0 ÷ 1
Manual
Automatic
Functional description
Allows the change of gas type. See "Gas
conversion" on page 186
Allows the amount of gas to be increased or
decreased in the ignition phase in case of
difficult starting.
Allows the fan speed to be increased or
decreased in the ignition phase in case of
difficult starting.
cod. 3541V280 - Rev. 00 - 03/2021
Default
55°C
30
RAGGIO 28 C = 100%
RAGGIO 34 C = 100%
--
--
10°C
10°C
10
18°C
43°C
4 bar/10
7 bar/10
10°C/second
10°C
60
0
Manual
in the top left corner of the screen.
Range
NG/LPG
-9 ÷ 20
-16 ÷ 14
Default
NG
0
0
193