Lamborghini Caloreclima RAGGIO C Instrucciones De Uso, Instalación Y Mantenimiento página 178

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Connection with coaxial pipes
fig. 14- Examples of connection with coaxial pipes (
For coaxial connection, fit the unit with one of the following starting accessories. For the wall dril-
ling dimensions refer to the figures fig. 39, fig. 40 and fig. 41 . Any horizontal sections of the fume
exhaust must be kept sloping slightly towards the boiler, to prevent possible condensate from
flowing back towards the outside and causing dripping.
Ø 100
Ø 60
041096X0
Table 2- Max. length coaxial ducts
Max. permissible length (horizontal)
Max. permissible length (vertical)
Reduction factor 90° bend
Reduction factor 45° bend
178
fig. 15- Starting accessories for coaxial ducts
Coaxial 60/100
cod. 3541V280 - Rev. 00 - 03/2021
= Air /
= Fumes)
041095X0
7 m
8 m
1 m
0.5 m
RAGGIO C
Coaxial 80/125
20 m
0.5 m
0.25 m
EN
Tabla de contenido

Solución de problemas

loading

Tabla de contenido