Lamborghini Caloreclima RAGGIO C Instrucciones De Uso, Instalación Y Mantenimiento página 191

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

RAGGIO C
Code Description
Variable input contact
B06
operation selection
Relay card LC32 selec-
B07
tion
Hours without DHW
B08
draw-off
B09 Fault 20 status selection
B10 Not implemented
B11 Flowmeter timing
B12 Modulation Delta
B13 Not implemented
Pump antiblock opera-
B14
tion time
Flowmeter type selection
B15
(b01=3)
Fan frequency in standby
B16
mode
B17 NOT IMPLEMENTED
DHW mode activation
B18
flow rate
DHW mode deactivation
B19
flow rate
B20 Flue material selection
PVC flue maximum tem-
B21
perature
CPVC flue maximum
B22
temperature
Standard flue shutdown
B23
maximum temperature
PVC flue shutdown maxi-
B24
mum temperature
CPVC flue shutdown
B25
maximum temperature
Flow temperature limit in
B26
automatic calibration
Maximum temperature
during calibration in DHW
B27
mode
EN
Range
Flow meter exclusion
System thermostat
Second room therm.
Warning/Alert
Safety thermostat
External gas valve
Alarm
System filling solenoid valve
Solar 3-way valve
Second heating pump
Alarm2,
Burner lit
Frost protection active
0 ÷ 24 hours (time for temporary deactivation of comfort
mode without draw-off)
Deactivated
Enabled
--
Deactivated
1s ÷ 10s (seconds)
0 ÷ 30°C/10
--
0 ÷ 20 seconds
Flow. (450 imp/l)
Flow. (700 imp/l)
Flow (190 imp/l)
0 ÷ 100%
0 ÷ 100L/min/10
0 ÷ 100L/min/10
0 = Standard
1 = PVC
2 = CPVC
60 ÷ 110°C
60 ÷ 110°C
60 ÷ 110°C
60 ÷ 110°C
60 ÷ 110°C
25°C ÷ 55°C
75°C ÷ 95°C
cod. 3541V280 - Rev. 00 - 03/2021
Default
Second room thermostat
System filling solenoid valve
24
Enabled
--
Deactivated
0°C/10
--
5
Flow (190 imp/l)
0%
--
25
20
0
88°C
93°C
100°C
93°C
98°C
30°C
80°C
191
Tabla de contenido

Solución de problemas

loading

Tabla de contenido