QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control unit and set it at work immediately.
We recommend following these instructions, in order to check quickly the correct operation of control unit, motor and accessories, and
then changing the configuration in case of any non-satisfactory parameter.
Please refer to the paragraph "CONTROL UNIT CONFIGURATION" for the item position inside the menu, as well as for the available
options for each item.
1. Call up the default configuration: see paragraph "LOADING OF DEFAULT PARAMETERS"
2. Set items StoP, Fot1, Fot2, CoS1, CoS2 e FC.En according to the safety devices installed on the gate.
3. Start the self-learning cycle (item APPr).
This last operation will close the configuration menu and store set up parameters.
Self-learning procedure:
• In case the end of stroke or the obstacle sensor has been enabled, the gate will be activated in closing direction until the stop
end or the closing end of stroke is reached.
• In case NEITHER the ends of stroke OR the obstacle sensor have been enabled, be sure that the gate is completely closed when the
procedure is started up.
• The gate will be activated in opening direction until the stop end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize that they do not signal the position to the control unit, you
must send a START command when the gate reaches its max. opening position.
• The gate will be activated in closing direction until the stop end or the closing end of stroke is reached.
• In case the sensors have not been enabled, or if you realize that they do not signal the position to the control unit, you
must send a START command must be sent when the gate reaches its fully closed position.

CONTROL UNIT CONFIGURATION

In the following page there is the step-by-step procedure to set all operation parameters of Pd8 control unit.
You can either follow all procedure steps and perform a complete control unit configuration or select and adjust interesting items only.
As for both cases, you will have to perform the right exit procedure through item FinE, in order to activate your new configuration.
Pd8 control unit provides for a self-learning procedure of working times; therefore, we recommend that you set up a standard
configuration first (see previous paragraph), then you carry out the self-learning and finally you change any unsatisfactory items.