V2 GOLD400D Manual Del Usuario página 40

Ocultar thumbs Ver también para GOLD400D:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Slowing down time
In case this function is enabled, during the last seconds of motion, the
control unit will give motor a reduced power command, to avoid a
strong impact with the stop end. t.AP is the max. allowed time.
m
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to
measure both opening and closing times, and to enable it again once
the setup has been carried out. The control unit will automatically
consider the working time delay caused by the slowing down.
• If partial opening time t.APP is shorter than t.AP, there will be no
slowing down during the pedestrian cycle opening.
Start command during the opening phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the opening phase.
PAUS
The gate stops and goes to pause
ChiU
The gate immediately starts closing
no
The gate go on with the opening phase (command is ignored)
Select option PAUS, to set up the "step-by-step" operation logic.
Select option 'no', to set up the 'always open' operation logic.
Start command during the closing phase
This menu allows fixing the control unit conduct in case it receives a
Start command during the closing phase.
StoP
The gate stops and its cycle is considered as finished
APEr
The gate opens again
Select option StoP, to set up the "step-by-step" operation logic.
Select option APEr, to set up the 'always open' operation logic.
Start command during the pause
This menu allows fixing the control unit conduct in case it receives a
Start command when the gate is open during its pause phase.
ChiU
the gate starts closing
no
command is ignored
Select option ChiU, to set up the "step-by-step" operation logic.
Select option 'no', to set up the 'always open' operation logic.
Apart from selected option, the start command lets the gate close if it
has been stopped by a stop command or if the automatic closing was
not enabled.
38
Tabla de contenido
loading

Este manual también es adecuado para:

Gold800dGold1200d

Tabla de contenido