Safety ribbon 2 input
This menu allows enabling the input for type 2 safety ribbon, that is to
say mobile ribbons (see paragraph "Installation").
no
input disabled (ignored by the control unit).
No jumper with the common is required.
Si
input enabled.
Enabling WIRELESS edges
This menu makes it possible to enable the edge input to operate with
V2 WIRELESS edges
no
Input disabled
Si
Input enabled
End of Stroke Inputs
Pd8 control unit allows connecting magnetic limit switch which are
activated by the door motion and showing to the control unit that each
door reached its position of complete opening or closing.
no
end of stroke inputs are disabled
Si
end of stroke inputs are enabled
Anti-skid
When an opening or closing operation is interrupted by a command or
for the intervention of the photocell, the set-up time for the opposite
movement would be excessive, so the control unit operates the motors
only for the time necessary to recover the actually covered journey.
This could be not sufficient, particularly in the case of very heavy gates,
as because of the inertia at the inversion moment the gate runs an extra
space in the previous direction that the control unit is not able to take
into account.
If after an inversion the gate does not return exactly to the starting
position, it is possible to set an anti-skid time that is added to the time
calculated by the control unit in order to recover the inertia.
m
WARNING: If function ASM is disabled, the gate goes
backward until it comes to the end stops. In this phase the
control unit does not activate the slow down function before the
end stops are reached and any obstacle that comes across after
the inversion is considered as an end of stroke.
Obstacle Sensor Enabling
This menu allows the sensitivity adjustment of the obstacle sensor over
10 levels, from 1 to 10. By setting up "0", sensors will be disabled,
increasing the value the sensivity increase.
The control unit automatically adjusts the sensor on the most suitable
level, according to each motor set up power.
In case the safety operation is deemed not to be fast enough, the
sensitivity level can be slightly increased.
If the gate stops where no obstacles are present, you should reduce
the sensitivity level.
(See paragraph "Obstacle sensor operation" hereafter).