Electrical Installation - Festo DHTG Instrucciones De Utilizacion

Ocultar thumbs Ver también para DHTG:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
DHTG
5.3

Electrical installation

If proximity switches are used for position sensing:
Note
Faulty switching or damage to the proximity
switches due to being screwed in too far.
• Make sure the proximity switches are
screwed into the thread (U), (V) or (W) up to
the following maximum depth.
Max. screw-in depth
Size
Thread (U), (W)
Thread (V)
Tab. 8
• Screw the proximity switches into the following threaded holes:
Sensing
Direction of rotation
Locking mechanism
Piston end position
Tab. 9
When the DHTG is used with 3-part split (DHTG-140 and DHTG-220):
Note
Based on the design, the rotating plate can engage in an intermediate position
(corresponding to the 6-index stations).
• After an emergency stop / overload, make sure that the rotating plate is in the
desired position before the system is placed back in operation.
If the rotating plate is engaged in an intermediate position, bring the locked
rotating plate into the desired position by jerking and twisting it against the
overload protection.
Festo – DHTG – 1303c English
65
[mm]
11.5
[mm]
19.7
Direction of rotation of plate
Clockwise rotation
(W)
(V)
(U)
(U)
(W)
(V)
Fig. 8
90
140
11.5
13.5
14
16
Anti-clockwise rotation
(reciprocating operation/
flexible control)
(U)
(V)
(W)
220
18.5
21
27
Tabla de contenido