Periodic Maintenance And Checks - RCM R. 703 H SACK/1 Manual De Uso Y Mantenimiento

Tabla de contenido
68
1) The motor-sweeper must be inspected by a specialist technician who checks its safety or for any damage or defects in the
following cases:
before it is put into operation
after modifications or repairs
at regular intervals, as indicated in the "Routine maintenance and control operations" table.
2) Every six months check that the safety devices are in good working order; the inspection must be made by authorized
specialist staff.
3) To ensure the sweeper performance, the machine must be overhauled by RCM staff every 5 years.
4) The person in charge of the machine must make an annual check on its condition. During this check, he must decide whether
the motor-sweeper still complies with the current safety regulations, and then apply a marker plate to the machine to indicate
that the check has been made.

Periodic maintenance and checks

1
Check motor oil level
2
Check motor air filter cartridges
3
Replace motor oil
4
Check stretching belts
5
Check battery water level
6
Replace hydraulic oil filter cartridge
7
Replace fuel filter
8
Check hydraulic oil level
9
Replace hydraulic oil
Check that the main brush is free from wires, strings,
10
etc...
11
Check dust filters
12
Lubricate steering chain and check stretching
13
Replace dust filters
R 703 H SACK/1
MOTOSCOPE INDUSTRIALI
Periodic maintenance and checks
Every ... hours
8
40
100
500
1500
Tabla de contenido
loading

Tabla de contenido