70
1) The motor-sweeper must be inspected by a specialist technician who checks its safety or for any damage or defects in the
following cases:
•
before it is put into operation
•
after modifications or repairs
•
at regular intervals, as indicated in the "Routine maintenance and control operations" table.
2) Every six months check that the safety devices are in good working order; the inspection must be made by authorized
specialist staff.
3) To ensure the sweeper performance, the machine must be overhauled by RCM staff every 5 years.
4) The person in charge of the machine must make an annual check on its condition. During this check, he must decide whether
the motor-sweeper still complies with the current safety regulations, and then apply a marker plate to the machine to
indicate that the check has been made.
Periodic maintenance and checks
1
Check level of water in batteries
2
Check carbon brushes of suction fan and drive motors
Check that the main brush is not entangled with string,
3
wire, etc.
4
Check filter cartridges
5
Replace filter cartridges
6
Check main brush trace
7
Check tension of the belts
8
Grease steering chain
R 703 E SACK/1
R 703 E SACK/1
R 703 E SACK/1
R 703 E SACK/1
R 703 E SACK/1
MOTOSCOPE INDUSTRIALI
Periodic maintenance and checks
Every ... hours
8
40
125
500
•
•
•
•
•
•
•
1500
•