Removal: The Grip Anchorage Connector must be removed at the end of the day. Never leave a
unit inserted in a hole overnight. To remove the unit, place your thumb inside the anchor loop and
your first two fingers around the trigger. Retract the trigger and remove the unit slowly and gently.
If the Grip becomes stuck, insert a punch, screwdriver or pointed object into the hole until the tip
rests on the striker plate (see Fig. 7c). Give a LIGHT, blunt tap with a hammer or heavy object.
The striker plate will be easily visible at the edge of the hole.
Fig. 7c
Blow off unit with compressed air after each use. Clean and store according to instructions.

3.8 D-Bolt Anchor (416)

The D-Bolt Anchor is designed to provide a single user with an easily installed anchorage con-
nector.
Warnings and Limitations
• For use by ONE person only. Maximum capacity is 400 lbs. (181.4kg), including tools. —
DO NOT EXCEED THIS WEIGHT.
• Use only locking carabiners,
locking snap hooks or other
Miller approved connectors or
connecting devices to attach
to this equipment.
• The structure that this product
is attached to must be capable
of supporting a 5,000 lb.
(22.2kN) static load or provide
a 2:1 safety factor in the direc-
tion of pull.
E n gli sh
(76.2mm)
Working Thickness up to 4"
(101.6mm)
14
3"
4.125"
(104.8mm)
Fig. 8a
1.5"
(38.1mm)
Warning Label