Figura 46
Código de la clave común (para la descripción breve del diseño del contador de gas, indicado en
la placa de características* y la hoja de datos del instrumento **)
Type Code FLOWSIC600
Group
Key code
1
METER BODY
Path configuration
1-Path
2-Path
4-Path
1+1-Path redundant
2+2-Path redundant
4+4-Path (Quatro)
4+1-Path (2plex)
2-Path crossed
4-Path crossed
2-Path Special
Overall length
2
2D
3D
4D
5D
6D
Shortened Meter body
Other size
Nominal size
3
2" / DN 50
3" / DN 80
4" / DN 100
6" / DN 150
8" / DN 200
10" / DN 250
12" / DN 300
16" / DN 400
Other size
Connection flange type
4
ASME B16.5 / ASME B16.47 (>24")
DIN EN 1092-1
GOST 12815-80 / 12821-80 / GOST-R 54432-2011
NORSOK L 005
TECHLOK
Grayloc
EN 1759-1
Other type
Connection diameter
5
Schedule ####
Specified in [mm] (DIN)
Flange type / sealing face
6
Raised Face (ASME B16.5 / B16.47)
Ring Type Joint (ASME B16.5 / B16.47)
Form B1 (EN 1092-1 / 1759-1)
Form B2 (EN 1092-1 / 1759-1)
Form # Inlet / Form # Outlet (EN 1092-1 / 1759-1)
Version V# (GOST 12815-80 / 12821-80)
Type T# (GOST-R 54432-2011)
Special design
Material
7
Carbon Steel
Stainless steel
LT-CS
Duplex
Superduplex
Superaustenit
Aluminium
Other material
8
Connection for Extraction Tool
Yes
No
9
ULTRASONIC TRANSDUCER
10
SIGNAL PROCESSING UNIT
Ex-proof-design
None
CSA Group D T4
CSA Group B, C, D T4
ATEX IIA T4, M20x1.5
ATEX IIC T4, M20x1.5
ATEX IIA T4, 1/2 NPT
ATEX IIC T4, 1/2 NPT
IECEx IIA T4, M20x1.5
IECEx IIC T4, M20x1.5
IECEx IIA T4, 1/2 NPT
IECEx IIC T4, 1/2 NPT
Power supply
11
12 ... 24V DC
12
Data outputs
Hardware variant 1 (4 digital outputs)
Hardware variant 2 (1 analog current output and 3 digital outputs)
Hardware variant 4 (1 analog current output and 2 RS485)
Hardware variant 5 (with integrated EVC, p- and T-transmitters externally power supplied, I/O board with DSP)
Hardware variant 6 (with integrated EVC, p- and T-transmitters internally power supplied, I/O board with DSP)
Hardware variant 7 (same as hardware variant 1, but with LowPressureAnalogBoard)
Hardware variant 8 (same as hardware variant 2, but with LowPressureAnalogBoard)
Hardware variant 9 (same as hardware variant 4, but with LowPressureAnalogBoard)
Hardware variant A (same as hardware variant 5, but with LowPressureAnalogBoard)
Hardware variant B (same as hardware variant 6, but with LowPressureAnalogBoard)
13
HART-Protocol (By selection of hardware variant 2 and 8 only)
Yes
No
14
Front panel
LED SICK
LCD SICK
15
Custody transfer design meter
Yes
No
Rev. 1.12
2013/05
* Véase pág. 137, Figura 64
** La hoja de datos del instrumento está incluida en el informe de datos del fabricante (MDR).
112
1
2
3
4
FL600-
1
P
2
P
4
P
1
R
2
R
4
R
5
C
2
X
4
X
2
S
2 D
3 D
4 D
5 D
6 D
S D
X D
0 2
0 3
0 4
0 6
0 8
1 0
1 2
1 6
# #
C
L
#
#
P
N
#
#
P
N
#
#
N
K
#
#
I
N
X
X
G
R
X
X
C
L
#
#
X
X
X
X
(Will be selected by SICK on the basis of the technical data )
*
FLOWSIC600 · Instrucciones de servicio · 8013761/YUK2/V 4-0/2016-07 · © SICK Engineering GmbH
5
6
7
8
#
#
#
#
#
#
#
#
#
#
#
#
#
#
X
X
S
C
#
#
#
#
#
#
#
#
.
#
R F
R J
B 1
B 2
# #
V #
T #
X X
0
1
2
3
4
5
6
X
Y
N
9
10
11
12
13
14
15
-
-
_
_
0
1
2
3
4
5
6
7
8
9
A
D
C
1
2
4
5
6
7
8
9
A
B
Y
N
0
1
Y
N
# ... to be specified by SICK
*
... only design of USM, no restriction to type approval
( 4P; 5C; 4R --> Y / other path configurations --> N)
E_69423
Apéndice