Operating Instructions
WTS Models
General Safety Information
(Continued)
INSTALLING A SHUT-OFF VALVE
A shut-off valve should be installed on
the discharge port of the tank to con-
trol the air flow out of the tank. The
valve should be located between the
tank and the piping system.
Never install a
shut-off valve
between the compressor pump and the
tank without an appropriate safety
valve. Personal injury and/or equip-
ment damage may occur. Never use
reducers in discharge piping.
When creating a permanently installed
system to distribute compressed air,
find the total length of the system and
select pipe size from the chart. Bury
underground lines below the frost line
and avoid pockets where condensation
can gather and freeze.
Apply air pressure to the piping installa-
tion and make sure all joints are free
from leaks BEFORE underground lines are
covered. Before putting the compressor
into service, find and repair all leaks in
the piping, fittings and connections.
Operation
WIRING
1. Local electrical wiring codes differ
from area to area. Source wiring, plug
and protector must be rated for at
least the amperage and voltage indi-
cated on motor nameplate, and meet
all electrical codes for this minimum .
2. Use a slow blow fuse type T or a cir-
cuit breaker.
Table 2
Length of Cord (ft)
Gauge of Cord
Table 1
Wire
Power cord
Motor cord
Power cord
Motor cord
(✽) When the unit is not in operation
damage will result from inadequate
wiring, etc.
NOTE: 120 volt, 10 and 13 amp units
can be operated on a 115 volt, 15 amp
circuit under the following conditions:
a. No other electrical appliances or
lights are connected to the same
branch circuit.
b. Voltage supply is normal.
c. Extension cords are of the minimum
gauge specified in this instruction
manual.
d. Circuit is equipped with a 15 amp cir-
cuit breaker or a 15 amp slow blow
fuse type T.
3. If above conditions cannot be met or
if nuisance tripping of current pro-
tection device occurs, it may be nec-
essary to operate compressor from a
115 volt, 20 amp circuit.

GROUNDING INSTRUCTIONS

1. This product should be grounded. In
the event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
Extension cords for 120V/15 Amp Unit
25
50
100
14
10
10
✽ Wire and Terminal Guide
Color
White
White
Black
Black
Overheating, short
circuiting and fire
adapter. Improper use of grounding
plug adapter can result in a possible
risk of electrical shock!
2. If repair or replacement of cord or
3. Check with a qualified electrician or
150
200
250
8
6
6
3
Terminal
Hot
Line
No
Load
No
Line
Yes
Load
Yes
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.
Grounded
Outlet
TEST
Grounding
Pin
Figure 1 - Grounding Method
Do not use
grounding
plug is necessary, do not connect
grounding wire to either flat blade
terminal. The wire with insulation
having an outlet surface that is green
with or without yellow stripes is the
grounding wire.
serviceman if grounding instructions
are not completely understood, or if
in doubt as to whether product is
properly grounded. Do not modify
300
400
4
4
RESET
500
2