4. Assembly and initial use

Note: It is necessary to use an electrode holder that complies with the
NMX-J-038/11-ANCE standard. Use a helmet in accordance with regulations and that has
protective glasses in accordance with regulations, the level of protection (shade) must be
at least 9-10. There should be a slag hammer and wire brush. Before assembling make
sure that the power switch is turned off and that the power socket of the equipment is
disconnected.
Connect the work cable to the ground socket with the negative (-) symbol (MMA)
Connect the torch to the ground socket with the negative symbol (-) (TIG)
Insert the coupling into the socket, and then turn it clockwise until it clicks. Pull on the
coupling device to ensure it is properly coupled. These coupling devices must be clean
and free of oil.
Connect the electrode cable to the socket with the positive symbol (+). (MMA)
Connect work cable to socket with positive (+) symbol. (TIG)
Insert the coupling into the socket marked positive (+), and then turn it clockwise. Pull on
the coupling device to verify that it is properly coupled. These coupling devices must be
clean and free of oil.

Power switch

This switch allows you to turn the equipment on and off with an audible click.

Transport Strap

Use it to transport the equipment easily and safely. The installation of the transport strap
is carried out in the slits in the upper part of the plastic housings of the equipment.

5. General Operation

Environment conditions

a) Operating ambient temperature: −10 ℃ ∼ + 40 ℃
Transport and storage temperature: −20 ℃ ∼ + 55 ℃
b) Relative humidity: Up to 50% at 40 ℃ and up to 90% at 20 ℃
c) Operating environment with normal levels of dust, acid, corrosive gases
that are not different from those produced by the welding process and that
allow adequate ventilation.
d) Equipment must be positioned less than 10 ° from the horizontal.
www.ELITETOOLS.co