N
M
L
K
P2
EMERGENCY
STOP
WH
RD
N.C.
EN1
PLATFORM
CONTROL
SW8
BOX
CONTROL
ACTIVATE
SWITCH
BK
WT
SW11
UP
BK
PLATFORM
DOWN
UP/DOWN
SWITCH
WH
EN4
GND
POWER TO
PLATFORM
GROUND
GFCI
STUD
GN/YL
RECEPTACLE
110V AC / 220V AC
BK
J
I
H
P1
EMERGENCY
BK
STOP
RD
BK
YL
W3
N.C.
1
2
3
NEGATIVE 12V DC INPUT
POSITIVE 12V DC INPUT
KS1
+
LEVELING
INDICATORS
GROUND/
L5
PLATFORM
POWER INDICATOR
BK
BK
L14 L12
N.O.
L6
-
BK
INDICATOR FOR
AUXILIARY LOWERING
BK
L15
L13
B4
8 AA
BATTERIES
1 SECOND TIME DELAY 12V DC OUTPUT
L7
SW12
DC MODEL:
LOW BATTERY
AUXILIARY
U10
INDICATOR
DOWN
N.O.
PC BOARD
WH
RD
GND
GN/YL
GROUND
STUD
GND
GROUND
STUD
CB1
15 AMP
QD7
POWER
STRAIN RELIEF
INPUT
PLUG
TO MOTOR
D5
POWER
QD3
1
2
3
4
6
7
SUPPLY
QUICK DISCONNECT A
AC
TO PLATFORM
1
2
3
4
6
7
RD
OR
BL
WH
GN/YL
BK
Primera edición • Segunda impresión
(modelos con número de serie entre 4096-105 y 4096-285)
G
F
E
U12
THERMAL
DEVICE
YL
U9
TRANSFORMER
BK
RD
16V AC INPUT
1
WH
RD/YL
BN
CENTER TAP INPUT
2
RD
BL
WH
16V AC INPUT
3
WH
4
LED14 12V DC INPUT
OR
5
LED12 12V DC INPUT
BL
LED13 12V DC INPUT
6
RD
7
LED15 12V DC INPUT
BK
12V DC OUTPUT
8
RD
12V DC OUTPUT
9
RD
12V DC OUTPUT
9A
GN/YL
GROUND
10
RD
12V DC MOTOR RELAY OUTPUT
11
BK
12
OR
12V DC UP SIGNAL INPUT
13
W4
QD4
BK
BK
7
7
RD
GN
6
6
WH
WH/BK
5
5
GN/YL
GN/YL
4
4
OR
OR
3
3
EN2
BL
GN
2
2
GROUND
WH
WH
1
1
CONTROL
BOX
POWER UNIT
GN/YL
WH
WH
M5
MOTOR
BK
BK
Y30
GND
N.O.
GROUND
DUMP VALVE
STUD
N° de pieza 38139SP
Sección 7 • Esquemas
Esquema eléctrico
Modelos de CA IWP Super Series
D
C
B
A
S7
TILT
SENSOR
RD
OR
BK
W6
TERMINAL
GND
STRIP
GROUND
STUD
N.O.
Y7
WH
PLATFORM
DOWN
BK
SW18
GN
BK
SW17
GN
BK
BK
PLATFORM
TO
OUTREACH
PLATFORM
OPTION
LS1
PLATFORM
EXTENTION
WH
BK
TO BASE
QUICK DISCONNECT A
QD3
TO PLATFORM
Genie AWP Super Series e Genie IWP Super Series
1
2
3
BK
WH
GN
4
5
6
7
8
7 - 25