Product Information; Technical Data - Wilo DrainLift XL Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para DrainLift XL:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
English
24
Application limits
The specified maximum volume flow applies for intermittent operation (S3 – 60% / 60 s,
i.e. max. 36 s operating time, min. 24 s idle time).
The unit may switch on a maximum of 30 times per hour per pump. The running time of the
pump may not exceed 36 s, including the follow-up time (follow-up time = pump running
time after the end of pumping water). The operating time and follow-up time (if required)
should be set as short as possible.
Furthermore, the operating parameters should be observed in accordance with Table 5.2.
WARNING! Danger due to overpressure!
If the lowest inlet head is higher than 5 m, this will cause dangerous overpressure in the
reservoir in the event of a unit failure. If this happens, there will be a risk of the tank
bursting. In case of malfunctions, the inlet must be blocked off immediately.
WARNING! Risk of burns!
Depending on the operating status of the system, the entire pump can become very
hot.
Touching the pump can cause burns.
Correct use of the pump/installation also includes following these instructions.
Any use going over and beyond the intended use is considered to be improper.

5 Product information

5.1 Type key
Example:
DrainLift XL 2/25 (3~)
DrainLift
Sewage lifting unit
XL
Size
2
2 = double-pump system
/25
Maximum delivery head [m] when Q=0 m³/h
(3~)
3~: Three-phase version
5.2

Technical data

Connected voltage
Connection version
Power consumption P
1
Nominal current
Mains frequency
Protection class
Speed
Operating mode
Max. switching frequency
Max. total delivery head
Max. permitted geodesic delivery head
Max. permissible pressure in the pressure pipe
Max. volume flow
Max. fluid temperature
Min. fluid temperature
Max. ambient temperature
Max. solid grain size
Sound pressure level
(depending on duty point)
Gross volume
Switching volume (switching level)
Max. inflow in one hour
(only at max. possible switching volume)
Minimum level for Pump ON switching point
Minimum level for Pump OFF switching point
DrainLift XL
2/10
2/15
[V]
3~400 ± 10 %
Switchgear with 1.5 m mains cable and
32 A CEE plug, pre-installed
[kW]
See unit name plate
[A]
See unit name plate
[Hz]
50
Unit: IP 67 (2 mwc, 7 days)
Switchgear: 65
[rpm]
2900
S1, S3-60 %/60 s
[1/h]
60 (30 per pump)
[mWS]
10
15
[mWS]
9
13
[bar]
3
[m³/h]
35
37
[°C]
40
[°C]
3
[°C]
40
[mm]
40
1)
[dB(A)]
< 70 *
[l]
380
[l]
260 (ON 550 mm)
[l]
15600
[mm]
550
[mm]
80
2/20
2/25
20
22
16
19
40
40
WILO SE 03/2011
Tabla de contenido
loading

Tabla de contenido