LUBRICATION
Ingersoll–Rand No. 10
Always use an air line lubricator with these tools.
We recommend the following Filter–Lubricator–Regulator
Unit:
For USA – No. C08–02–FKG0–28
Before attaching the air hose, place several drops of
Ingersoll–Rand No. 10 Oil into the air inlet. This should
be done each day even when an air line lubricator is used.
During the working day, check the tool to ensure that the
retainer components are lubricated.
After each two or three hours of operation, unless an air
line lubricator is used, place several drops of Ingersoll–
Rand No. 10 Oil into the air inlet.
Before storing Air Hammer or if the tool is to be idle
for a period exceeding 24 hours, pour about 3 cc of
Ingersoll–Rand No. 10 Oil into the air inlet and operate
the tool for 5 seconds. This will coat the internal parts
with oil and prevent rusting while the tool is idle.
Model
772
PLACING TOOL IN SERVICE
Never use a heavy oil or an oil that forms gum.
Either will clog the small parts, restrict valve motion
and cause loss of efficiency. If the operation of the
Hammer becomes sluggish, pour 3 cc of a clean, suitable
cleaning solution into the air inlet and operate the tool for
30 seconds. Lubricate in the regular manner immediately
after flushing.
SPECIFICATIONS
Blows
per min.
3,000
3
TO
MAIN LINES 3 TIMES
AIR
AIR TOOL INLET SIZE
SYSTEM
TO
AIR
TOOL
LUBRICATOR
FILTER
REGULATOR
BRANCH LINE 2 TIMES
AIR TOOL INLET SIZE
DRAIN REGULARLY
COMPRESSOR
(Dwg. TPD905–1)
Piston Stroke
in (mm)
2–1/4 (57)