Operation - Husqvarna DC 1400 Manual De Instrucciones

Ocultar thumbs Ver también para DC 1400:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning. Clean
the electrodes with a brush. Clean the
container with a damp rag and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-40/C-DN-40 accessories can
be connected.

Operation

Turning on the Appliance
 Plug in the main plug.
 Switch on the appliance at the main
switch.
Adjust the suction output
 Set the suction output (min - max) at the
rotary switch.
Working with electrical power tools
Danger
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
 Connect the mains plug of the electric
power tool to the vacuum cleaner.
 Switch on the appliance at the main
switch.
Indicator lamp is on; vacuum cleaner is in
the standby mode.
Note: The vacuum cleaner is turned on and
off automatically with the electric power
tool.
Note: The vacuum cleaner starts automat-
ically within 0.5 seconds and continues to
run for 15 seconds after the power tool has
being switched off.
10
Note: Please refer to "Technical specifica-
tions" for the power connection specifica-
tions of the power tools.
Illustration
 Adjust the stepped power tool adaptor
to fit the connection of the electric pow-
er tool.
Illustration
 Remove the elbow from the suction
hose.
 Attach the stepped power tool adaptor
to the suction hose.
Illustration
 Connect the adaptor to the electric pow-
er tool.
Automatic filter cleaning
The appliance has an innovative filter
cleaning system that is particularly effective
with fine dust. The flat pleated filter is auto-
matically cleaned every 15 seconds
through an air jet (pulsating sound).
Note: Automatic filter dedusting is switched
on at the factory.
Note: The automatic filter dedusting func-
tion can only be switched on/ off when the
appliance is switched on.
To switch off automatic filter cleaning:
 Activate the switch. Indicator lamp in
the switch goes off.
To switch on automatic filter cleaning:
 Press the switch again. Indicator lamp
in the switch glows green.
Turn off the appliance
 Switch off the appliance at the main
switch.
 Pull out the mains plug.
After each operation
 Empty the container.
 Vacuum and wipe the appliance inside
and outside with a damp cloth.
– 3
EN
Tabla de contenido
loading

Tabla de contenido