Parameter Setting For Wiring Options; Dipswitch; Description Of The Various Additional Devices; Photoelectric Cells - SOMFY ROLLIXO RTS Manual De Instalación

Ocultar thumbs Ver también para ROLLIXO RTS:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Rollixo RTS

8.2 Parameter setting for wiring options

Possible parameter

Dipswitch

setting
1
Cell self-test
2
Choice of cell type
3
Orange light 2s
warning
4
Choice of wired safety
edge type
5
Holiday mode parameter setting (see section 9.4)
6
Do not use
1
2
3
4
STOP
Prog

8.3 Description of the various additional devices

> Photoelectric cells
N.B.: In accordance with standard EN 12453 governing the safe use of
motorised gates and doors, the use of the TAHOMA control box to
automatically control a garage door or gate not visible to the user requires
the installation of a photoelectric cell type safety device with autotest on
the automatic control system.
Receiver
Dipswitch 1 Dipswitch 2
Without auto-
OFF
ON
test
With auto-test
ON
ON
If cells are removed, it is essential to create a bridge between
terminals 18 and 19.
It is compulsory to install photoelectric cells if:
- the automatic control device is being controlled remotely (user
unable to see it),
- automatic closure is activated.
24V Cell
Sec Cell
h
24V dc
TX
14
15
16
17
18
19
Copyright © 2014 Somfy SAS. All rights reserved.
ON
OFF
Activated
Deactivated
Photoelectric
Electric eye
Activated
Deactivated
Resistive
Optical
Comments
Requires checking for
correct operation every 6
months.
Enables an automatic
test to be carried out to
check the operation of the
photoelectric cells each time
the door moves.
If the operational test is
negative, closure is in
downgraded mode (press
and hold down
).
1
14
TX
Test
2
15
Sec
RX
20
1
16
2
17
RX
3
18
5
19
> Reflex photocell
N.B.: In accordance with standard EN 12453 governing the safe use of
motorised gates and doors, the use of the TAHOMA control box to
automatically control a garage door or gate not visible to the user requires
the installation of a photoelectric cell type safety device with autotest on
the automatic control system.
Receiver
Dipswitch 1 Dipswitch 2
Without auto-
OFF
OFF
test
With auto-test
ON
OFF
If cells are removed, it is essential to create a bridge between
terminals 18 and 19.
It is compulsory to install photoelectric cells if:
- the automatic control device is being controlled remotely (user
unable to see it),
- automatic closure is activated.
ref. 1841195
h
24V dc
14
15
Ref. 9013647
Without auto-test ON
With auto-test
h
24V dc
14
Comments
Requires checking for
correct operation every 6
months.
Enables an automatic
test to be carried out to
check the operation of the
photoelectric cells each time
the door moves.
If the operational test is
negative, closure is in
downgraded mode (press
and hold down
).
24V Cell
Sec Cell
Test
Sec
16
17
18
19
20
Brown
Blue
Black
Grey
Cell
Dipswitch 1 Dipswitch 2
ON
ON
ON
24V Cell
Sec Cell
Test
Sec
15
16
17
18
19
20
1
2
3
4
5
14
15
19
20
14
15
20
19
18
9

Capítulos

Tabla de contenido
loading

Tabla de contenido