Panasonic WV-Q169E Manual Del Usuario página 5

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2. Install two anchor bolts (locally procured: M10 recommended) into the concrete ceil-
ing.
q Install an anchor bolt in the
centre of the hole made in the
step 1.
w Determine
the
length by use of Template B
(accessory).
e Use Template B (accessory) to
decide the nut position, and fix
it.
(Mount the nut so that the dis-
tance between the bottom sur-
faces of the nut and ceiling is
adjusted to 134 mm.)
Note: If there is already an anchor bolt installed, the anchor bolt can be used as a 2nd anchor
bolt. Make sure that the distance between the 1st and 2nd anchor bolts is 1 000 mm or less
before use.
3. Mount the safety wire angle (accessory) on the 2nd anchor bolt and connect the safe-
ty wire (accessory) to the angle.
q Disconnect the safety wire from the safe-
ty wire angle.
w Engage the face marked q with the
anchor bolt.
e Bend the face marked w.
r Connect the safety wire to the safety wire
angle again.
Note: To use the anchor bolt that was already installed, the use of 2 spacer nuts (locally pro-
cured) is helpful.
anchor
bolt
Template B
Ceiling board
Spacer nuts
(locally procured)
Safety wire
2nd Anchor bolt
(locally procured)
Anchor bolts
Anchor bolt
w Insert
q Disconnect
Safety wire
Mark q
Safety wire angle
1st Anchor bolt (locally procured)
Nut (locally procured)
Determine the anchor
bolt length
Install the anchor bolt in the centre
of the hole
Upper side
Mark w
e Bend
Lower
side
r Connect
Spacer nuts
Safety wire angle
Existing anchor bolt
134 mm
5
Tabla de contenido
loading

Tabla de contenido