to replace the power cord, proceed as follows:
a.
Remove the top and bottom interlocking covers (fig. 28).
b. Unscrew the 6 screws that lock the front cover (fig. 29).
c. Remove the front cover (fig.30).
d. Unscrew the four fixing screws (X2) (fig. 31).
e.
Remove the front cover of the switchgear (X1) (fig. 31).
f. Unscrew the cable clamp (J1) (fig. 32).
g. Unscrew the cables locking screws of the terminal board (J2).
h. extract the old cable and insert the new one by following the same path.
i.
lock the three poles of the cable in the terminal board (J2) and tighten the screws.
l.
lock the cable using the strain relief (J1).
m. Close the switchgear.
n. reassemble the front cover of the machine.
o. Refit the two wedged-in covers upper and lower.
This operation must be performed by specialized personnel possessing the requirements indicated
by law.
2.3.3 -
TOP/BOTTOM INSTALLATION CONFIGURATION
The unit can be installed both in the lower part (adjacent to the floor) and in the upper part (adjacent to the
ceiling) of the wall.
Depending on installation (ceiling or floor) it is sufficient to change the electronic configuration so as to opti-
mize the aperture angles of the air outlet flap.
AIR OUTLET FLAP CONFIGURATION CHANGE FROM LOW WALL TO HIGH WALL AND VICE VERSA
Work as follows (see fig. 33-34):
a. Delicately open the flap and detach it from its side and central hooks on the deflectors.
b. Remove the pin (P1) and rotate the flap 180°.
c. Insert the pin (P1) on the right side of the flap.
d. Re-insert the flap by inserting the pin (P1) in the lower hole located on the right of the opening (P2) and
insert the pin already located in the appliance in the lower hole located on the left of the opening.
For correct operating of the appliance, every time that the configuration of the air outlet flap is
modified, there must always be a corresponding respective electronic control setting (see para-
graph 5.6.2).
2.4 - INSTRUCTIONS FOR INSTALLATION UNICO WALL
to obtain the best results and optimum performance, follow the instructions for correct installation provided
in this manual.
A failure to implement the indicated standards, which may cause a malfunction
of the appliances, relieves OLIMPIA SPLENDID from any form of warranty and
from any liability for possible damages caused to people, animals or things.
The electrical system must be compliant with legal standards, must respect
the data in the technical data sheet and be must be equipped with an efficient
ground system.
EN - 16