At this point the current configuration of the machine will be displayed for a few moments as indicated below:
LED A (red) on: appliance fitted with heat pump function;
LED B (green) on: installation to the lower part of the wall (to the ground) (factory installation);
LED C (yellow) on: installation to the upper part of the wall (to the ceiling);
LED D (green) on: reset settings function after an active black-out (factory setting).
Then, all of the LEDs on the console will start flashing simultaneously for 10 seconds.
During this phase, it is possible to change the previously displayed setting related to the type of installation
of the equipment by means of the micro key.
Configuration of the electronic control for installation to the upper part of the wall determines an
automatic correction of the room temperature detected of 3°C.
At this point the self-diagnostic function activates the appliance in heating mode (if fitted with the heat pump
function) for approx.2 minutes and then in cooling mode for another 2 minutes.
it is possible to terminate the function prematurely simply by switching the appliance off using the remote
control.
Should the conditioner block and signal an error, specify the LEDs that are flashing to the service centre in
order to facilitate the intervention.
DESCRIPTION
UniCo unit internal exchanger overtemperature (Hti)
UniCo unit external exchanger overtemperature (Hte)
UniCo unit outdoor temp. probe fault (short circuit) (tfS7)
UniCo unit outdoor temperature probe fault (open circuit)
(tfS8)
UniCo unit internal fan malfunction (Sv)
UNICO unit insufficient exchanger temperature (CF/RL)
UniCo unit condensation water maximum level (of)
UniCo unit eeprom parameters not valid (CKS)
UniCo unit ambient temperature probe fault (short circuit)
(tfS1)
UniCo unit ambient temperature probe fault (open circuit)
(tfS2)
UniCo unit internal exchanger temperature probe fault
(short circuit) (tfS3)
UniCo unit internal exchanger temperature probe fault
(open circuit) (tfS4)
UniCo unit external exchanger temperature probe fault
(short circuit) (tfS5)
UniCo unit external exchanger temp. probe fault (open
circuit) (tfS6)
SPlit unit malfunction
: flashing
EN - 30
LED D
LED C
LED B
GREEN
YELLOW
GREEN
off
off
off
off
off
on
off
off
off
on
off
on
off
on
on
off
on
off
on
off
on
on
on
on
on
on
on
on
on
off
LED A
RED
on
off
on
on
off
off
off
on
off
on
off
on
on
on
off
off
on
off
on
on
off
off
off
on
on
off
on
on
off
on