5. In a cold environment, when power is applied to the heaters, the malfunction light will be lighted as the fluid
level drops.
6. After flushing, seek medical attention immediately. (See "Warning", page 1.)
7. Safety and supervision personnel must be notified that the unit has been used and must be refilled.
Inspection and Maintenance
1. Power cord must be in good condition and plugged into a grounded outlet.
2. "Power On" light must be on when the unit is plugged in. If power light is not on, the outlet may not have
power or the safety fuse may have blown. The Fendall Porta Stream III must be immediately withdrawn
from service until authorized repairs are made. If the unit will be exposed to freezing temperatures, fluid
must be drained immediately.
3. "Malfunction" light: When this light or alarm is on, or is cycling on and off, a malfunction has occurred or
the solution level is low when the surrounding environment's temperature is below 60°F (15.6°C). Check
the solution level and refill if necessary. If the malfunction light or alarm is still on, check the unit
temperature by carefully touching the side of the unit. If the unit is very warm to the touch, the Fendall
Porta Stream III must be immediately withdrawn from service until authorized repairs are made. If the unit
will be exposed to freezing temperatures, fluid must be drained immediately.
4. "Heater" light: This light will be on when the solution temperature drops below the minimum temperature of
60°F (15.6°C) and power is supplied to the heaters. The "Heater" light will remain off when the solution
temperature is above the minimum temperature. If the "Power On" light is on and the unit is very cold to
the touch, the Fendall Porta Stream III should be immediately withdrawn from service until authorized
repairs are made. If the unit will be exposed to freezing temperatures, fluid must be drained immediately.
Inspection
An individual or department must be assigned the task of checking all self-contained eyewash units on a
weekly schedule to ensure the unit is in proper operating condition with adequate levels of flushing fluid.
Records of these weekly inspections should be kept with the unit. Eyewash units containing Sperian Saline
Solution or Sperian Water Additive should be cleaned and refilled per the solution manufacturer's
recommendations. Units containing just water need to be cleaned and refilled once a week. Use of a fluid
beyond the expiration date may result in serious personal injury. (See "Warning," page 1.)
NOTE: The Sperian Saline Solution contains a specially formulated salt compound. There may be a white residue if solution has
dried on the Fendall Porta Stream III surfaces. The white residue can be removed by wiping with a damp cloth.
To replace the flushing fluid in the Fendall Porta Stream III:
1. Drain the Fendall Porta Stream III of any remaining flushing fluid by pulling the rubber strap from the
nozzles and allowing the unit to empty until there is no flow from the nozzles. Remove the Fendall Porta
Stream III from the wall bracket (or level surface), open the fill cap and empty any remaining solution. (Use
of the Fluid Disposal Cart is recommended for easy collection and disposal.)
2. Rinse the unit with clean tap water, agitate thoroughly, then invert the station until the water is drained.
3. Partially fill the unit with clean tap water and allow to drain through the eyewash nozzles. If nozzle holes
are blocked, they may be opened by gently inserting a small wire or pin to remove obstructions. If
obstructions cannot be removed, contact Sperian, Inc., for replacement nozzles. Invert the unit to drain
any remaining water.
4. Reassemble the unit and fill per the instructions under the heading "Fill the Fendall Porta Stream III" in
this booklet.
netzerotools.com
1. When filled with flushing fluid, the Fendall Porta Stream III weighs approximately 150 lbs.
(70 kg). Provide the necessary equipment or personnel to install or remove the filled
Fendall Porta Stream III from the mounting bracket.
2. Install the mounting bracket so the Fendall Porta Stream III is level.
3. Read all warning notices on the concentrate bottle before mixing.
4. Wear suitable eye protection and gloves when mixing the concentrate.
5. Do not add any product or material to the solution of Sperian Saline Concentrate and water.
6. Connect to 110 volt/single phase/60hz/minimum 15 amps.
Use grounded outlet only. Do not use extension cords unless of proper gauge and capacity.
Do not modify power cord. A ground fault interrupter is recommended.