Honeywell Fendall Porta Stream III Manual De Instalación Y Funcionamiento página 3

Estación lavaojos de emergencia calentada de 15 minutos
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1. Wear protective eyewear and gloves and follow sanitary practices
during mixing.
2. Use a clean container of sufficient capacity, to mix 16 gallons (61 liters).
3. Add approximately 5 gallons (19 liters) of tap water to the container.
4. Add 1/3 of the concentrate to the container and agitate or mix thoroughly.
5. Repeat steps 3 and 4 adding sufficient water and concentrate to make a
total of 16 gallons (61 liters) of solution.
6. Place insulated jacket on unit.
7. Plug the unit into the outlet.
8. Ensure that the nozzles and pull strap are clean and dry. Thread pull strap through web belt loop on
backside of jacket door. Position nozzle covers (located at each end of pull strap) over left and right
nozzles, ensuring that the covers are fully seated on the nozzles. Place jacket door over basin with
9. Pour the mixed solution into the unit.
10. If your eyewash station is equipped with a separate vent cap, replace the vent cap. Close the fill cap and
attach a security device or inspection tag if desired.
11. Properly dispose of the concentrate bottle. Do not reuse.
12. Solution must be replaced 6 months after mixing.
13. "Power On" light must be lighted. If Power On light does not illuminate, remove the unit from service and
see "Maintenance," page 4. If fluid is cold, the "Heater" light must come on. If Heater light does not
illuminate, remove the unit from service and see "Maintenance," page 4.
14. Fendall Porta Stream III models #32-000310 are equipped with solution level switches to detect a low
solution level when the temperature drops below 60°F (15.6°C). Inspect the solution level switch through
the fill cap. The switch must be free-floating.
Sperian Water Additive Use
Use 1/2 oz. (15 ml) of preservative per gallon (3.8 liters) of water;
1. Wear protective eyewear and gloves and follow sanitary practices during mixing.
2. Use a clean container of sufficient capacity to mix enough solution to fill the eyewash unit. Solution may
also be mixed directly into the eyewash unit.
3. Add half of the required amount of water to the container.
4. Add the appropriate amount of preservative based on station capacity. Mix or agitate thoroughly.
5. Fill the station to the manufacturer's required level.
Any remaining preservative can be stored with the cap on for 120 days after opening. Station should be
cleaned and refilled every 120 days while using this product.
Operation
Employees must be instructed in the use of emergency eyewash stations. (See "Warning," page 1.) Studies
have shown that obtaining emergency flushing within the first 10 seconds in eye emergencies is critical. It is
required that training be provided to employees in each department where eye hazards exist. This training
should be scheduled on a regular basis to keep both current and new employees aware of the location of all
eyewash devices, as well as to reinforce the importance of obtaining immediate eye washing in emergencies.
1. The sooner the injured person can flush his eyes, the less likelihood there will be of eye damage. Seconds
can make the difference in preventing serious eye injury or blindness.
2. All employees must be reminded this unit is for emergency use only; tampering with
this unit or using it for non-emergency purposes may cause the unit to fail to operate
properly in an emergency situation.
In an emergency, the eyes may involuntarily clamp shut and the individual may be
experiencing pain, anxiety and disorientation. They may need assistance from other
workers in getting to and using the eyewash station.
1. Start the fluid flow by grasping the pull strap and pulling the strap upward.
2. When the fluid is flowing, place the injured person's left hand around the left nozzle
and the right hand around the right nozzle.
3. The injured person should then lower his head into the unit toward his hands.
4. When the eyes are in the streams of fluid, use the thumb and forefinger of each hand
to open the eyelids. Hold eyelids open until thoroughly flushed. 15 minutes is
recommended.
netzerotools.com
netzerotools.com
Nozzle Assembly
↑ up.
Tabla de contenido
loading

Este manual también es adecuado para:

32-000310

Tabla de contenido