HydroLift
Error messages
12 Error messages
Code
Description
E0
CPU Error
E1
Incorrect configuration
E2
Wrong coupling of the
wheel gripper
E3
Communication error
E4
Error height difference
E5
Emergency stop
E6
Error height sensor
E71
Short circuit
E72
Short circuit
E73
Short Circuit
E74
Short circuit
112
Possible causes
The processor has
detected an error.
Lifting unit from the active
group has been switched
off at the main switch.
Initially, error CL is
displayed.
When switching on again,
the remaining lifting units
show fault E1.
A second system sends on
the same frequency.
There is an invalid
configuration.
Aerial cable without
contact.
Aerial defective.
Radio modem defective.
Nominal load exceeded.
Unevenly distributed loads.
Battery charge too low.
Security notch blocked.
Error in the hydraulic
system.
Power supply interrupted.
Measuring signal of a
sensor outside the
permitted range.
Short circuit switching
relay 1 on the motor.
Short circuit switching
relay 2 on the motor.
Short circuit in main board.
Group message for
overload on a switching
relay.
Troubleshooting Steps
Acknowledge error message
with key "X".
If the problem persists,
contact Customer Service.
Acknowledge error message
on all lifting units with key
"X".
Reconfigure wheel gripper.
Check transmission
frequency of other radio
equipment in the area.
Acknowledge the error
message with the "X" key.
Check aerial and aerial
cable.
Check radio modem and
replace if necessary.
Correct difference in height
manually.
Check nominal load and load
distribution.
Charge batteries.
Check safety notches.
Unlock emergency stop.
Manually lower lifting units.
Replace sensor.
Check wiring of switching
relay 1. Replace switching
relay 1.
Check wiring of switching
relay 2. Replace switching
relay 2.
Replace circuit board.
Faulty component search.
1. Up-key (error?
Check/replace motor
protection and wiring).
126746