7.2.3) Level two functions (adjustable parameters)
Table 17: list of programmable functions: level two
Input LED
Parameter
L1
Motor force
Step-by-step
L2
Function
L3
Pause Time
Note: "
" represents the factory setting
All the parameters can be adjusted as required without any contraindication.
7.2.4) Level two programming (adjustable parameters)
The adjustable parameters are factory set as shown in the table 17 with: "
18. Follow the procedure carefully, as there is a maximum time of 10 seconds between pressing one key and another. If a longer period of
time lapses, the procedure will finish automatically and memorize the modifications made up to that stage.
Table 18: changing the adjustable parameters
1.
Press the key [Set] and hold it down (approx. 3 s)
2.
Release the [Set] key when L1 LED starts flashing
3.
Press the [
] keys to move the flashing LED onto the "input LED" which represents the function
which is to be changed
4.
Press the key [Set] and hold it down during step 5 and 6
5.
Wait approx. 3 seconds, after which the LED representing the current level of the parameter which is
to be changed will light up
6.
Press the [
] key to move the LED representing the value of the parameter
7.
Release the key [Set]
8.
Wait 10 seconds before leaving the program to allow the maximum time to lapse.
Note: Points 3 and 7 can be repeated during the same programming phases in order to set other parameters.
7.2.5) Level one programming example (ON-OFF functions).
The sequence to follow in order to change the factory settings of the functions for activating "High speed" (L2) and "Automatic Closing" (L3).
Table 19: Level one programming
1.
Press the key [Set] and hold it down (approx. 3 s)
2.
Release the [Set] key when L1 LED starts flashing
3.
Press the [
] key once to move the flashing LED to LED L2
4.
Press the [Set] key once to change the status of the function associated with L2 (Motor Speed).
LED L2 will now flash with long flashes
5.
Press the [
] key once to move the flashing LED to LED L3
6.
Press the [Set] key once to change the status of the function associated with L3 (Automatic Closing).
LED L3 will now flash with long flashes
7.
Wait 10 seconds before leaving the program to allow the maximum time to lapse.
Once these operations have been completed, LEDs L1 and L3 must remain on to indicate that the "High Motor Speed" and "Automatic
Closing" functions are active.
LED (level)
value
L1
Low
L2
Medium
L3
High
L1
Open – stop – close - open
L2
Open – stop – close - stop
L3
Condominium operation
L1
15 seconds
L2
30 seconds
L3
60 seconds
Description
Adjust the motor force sensitivity to suit the type of
door. The "High" adjustment is more suitable for large
and heavy doors.
Manages the sequence of controls associated to the
Step-by-Step input or to the 1st radio command (see
tables 6 and 7).
Adjusts the pause time, namely the time which lapses
before automatic closure. This will only have an effect if
automatic closing is active
" However, they can be changed at any time, as shown in Table
GB
Example
3s
SET
L1
SET
SET
SET
10s
Example
SET
3s
L1
SET
L2
SET
L2
L3
L3
SET
10s
17