Kenmore 119.16658011 Manual De Uso Y Cuidado página 20

Parrilla a gas de propano líquido
Ocultar thumbs Ver también para 119.16658011:
Idiomas disponibles

Idiomas disponibles

[]
[]
[]
Notes
about
LP Gas Tank
Exchange
Programs
Many retailers that sell grills offer you the option of
replacing your empty LP gas tank through an
exchange service. Use only those reputable
exchange companies that inspect, precision fill, test
and certify their tanks. Exchange your tank only for
an OPD safety
feature equipped tank as described
in the LP gas tank section of this manual.
Always keep new and exchanged LP gas tanks in an
upright position during use, transit or storage.
Leak test new and exchanged LP gas tanks BEFORE
connecting one to your grill.
How to Leak Test your
LP Gas Tank
For your safety:
All leak tests must be repeated each time your LP gas
tank is exchanged or refilled.
Do not smoke
when checking
for gas leaks.
Do not use an open flame to check for gas leaks.
Your grill must be leak tested outdoors in a
well-ventilated
area, away from ignition sources such
as gas fired or electrical appliances. During the leak
test, keep your grill away from open flames or
sparks.
Do not use household cleaning agents as damage to
gas assembly components can occur.
Use a clean paintbrush and a 50/50 mild soap and
water solution.
Brush soapy solution onto the LP gas tank in the areas
indicated by the arrows. See diagram.
If growing bubbles appear do not use or move the LP
Gas tank. Call an LP gas supplier or your fire
department.
Regulator
and LP Cylinder
Connections
The gas pressure
regulator
provided
with this
outdoor
cooking
appliance
must be used. This
regulator
is set for an outlet
pressure
of 11
inches water
column.
Regulator:
Your regulator
is equipped
with a Q.C.C. Type 1
quick connect
system,
ft will not allow gas to flow
until a positive
seal has been made.
ft has a
thermal
element
that will shut off the gas flow if
the temperature
reaches
240 degrees
F (115
degrees
C). ft also has a flow-limiting
device that
will restrict
the flow of gas to 10 cubic feet per
hour (0.28
cubic meters
per hour).
TO CONNECT
THE CYLINDER
TO THE
REGULATOR
AND HOSE
1.
Be sure the LP cylinder is "OFF" by turning
the hand
wheel clockwise
until it stops.
2.
Place the cylinder
into the base cabinet
panel of
the grill with the valve facing outward
and secure
with the cylinder
support
ring.
3,
Be sure all burner
controls
are turned
to the "OFF"
position.
4.
Remove the safety
cap from the cylinder
valve.
5.
Center the nipple of the regulator
into the
cylinder
valve.
6.
Turn the black nut clockwise
until it stops.
Hand
Tighten
Only,
Do Not Use A Wrench,
ff growing
bubbles
appear do not use or move
the LP Gas tank.
Contact
an LP gas Supplier
or
your fire department!
..............
"..
Type 1 connection
per
/
:.
-f'.':.'.-
"
.--'"" ANS Z21.58b-2006
:f
......
_"
>:'
..
..,-"
"
/ "r ............
Ooll#lng Nut
CAUTION:
When the appliance
is not in use
the gas must be turned
off at the tank.
20
loading