B1 - B2
230Vac courtesy or flashing lights
K1
Motor 2 (+)
K2
Motor 2 (ground)
K3
Motor 2 (-)
K4 - K5
12V electrolock
K6 - K7
24V courtesy or flashing lights
+24Vdc supply - photocell/optical edge TX for
K8
functional Test
K9
Accessory power common (-)
+24Vdc supply for photocells and other
K10
accessories
Open command for connecting traditional
J1
devices with N.O. contact
Pedestrian open command for connecting
J2
traditional devices with N.O. contact
J3
STOP command. N.C. contact
J4
Common (-)
J5
Exterior photocell. N.C. contact
J6
Interior photocell. N.C. contact
J7
Type 1 edges (fixed). N.C. contact
J8
Type 2 edges (mobile). N.C. contact
J9
Accessories common (-)
A1
Antenna shield
A2
Antenna
BATTERY
Battery pack (code 161212)
RECEIVER
Connector for MR1 receiver
Module interface
M1
Motor 1
24Vdc
Control unit power supply (+24 VDC)
Power Supply
Signals an overload on the accessory power
OVERLOAD
supply
PLEASE NOTE: the highlighted connections are
factory pre-wired

5 - CONTROL PANEL

5.1 - DISPLAY

When power is on, the control unit checks that display correctly
Pr I.0
operates by switching on all segments for 1.5 sec.
Firmware version, e.g.
1.5 sec.
Panel will be viewed upon completion of this test.
The control panel represents the physical status of the
terminal board contacts and of the program mode keys: if the
upper vertical segment is on, the contact is closed; if the lower
vertical segment is on, the contact is open (the above picture
shows an instance where the inputs PHOTO, PHOTO-I, EDGE and
STOP have all been correctly connected).
PLEASE NOTE: if the panel is off, the control unit should be
in ENERGY SAVING mode; press the OK key to turn it on.
Points being among display digits show the status of
programming push-buttons: as soon as a push-button is pressed,
its relevant point turns on.
The arrows on the left of the display show the state of the start
inputs. The arrows light when the related input is closed.
The arrows on the display right side show the gate status:
• The highest arrow turns on when the gate is into its opening
phase. If it blinks, it means that the opening has been caused
by a safety device (border or obstacle detector).
• The central arrow shows that the gate is on pause.
If it blinks, it means that the time countdown for the
automatic closing has been activated.
• The lowest arrow blinks when the gate is into its closing
phase. If it blinks, it means that the closing has been caused
by a safety device (border or obstacle detector).
53
8.8.8.8.