DISPLAY
DATA
LUCi
t.LUC
no
CiCL
AUS
tiM
biSt
Mon
SPiA
no
FLSh
W.L.
LP.PA
no / Si
Strt
no
StAn
AP.CH
PrES
oroL
StoP
no
invE
ProS
Foto
CFCh
no
Ch
Fot.i
APCh
no
Ft.tE
Si / no
CoS1
no
AP
APCH
CoS2
no
CH
APCH
Co.tE
no
Foto
rESi
FinE
no
Si
DESCRIPTION
Courtesy lights
- Timed function (from 0 to 20')
- Function deactivated
- On for the entire duration of the cycle
Auxiliary channel
- Timed function (from 0 to 20')
- Bistable operation
- Monostable operation
Low voltage output setting
- Not used
- Flashing function
- Warning light function
Flashing unit paused
Start inputs
- Inputs from terminal board disabled
- Standard operation
- Separate opening and closing commands
- Man-present operation
- Timer operation
STOP input
- The input is disabled: the STOP command is not received
- The STOP command stops the gate: The next START inverts the direction
- The STOP command stops the gate: The next START does not invert the direction
Exterior photocell input
- Functions as an active photocell during closure and with the gate stopped
- Disabled
- Only functions as an active photocell during closure
Interior photocell input
- Functions as an active photocell during opening and closure
- Disabled
Photocell testing
Edge 1 input (fixed edge)
- Input inactive
- Input only active during opening
- Input active during opening and closing
Edge 2 input (mobile edge)
- Input inactive
- Input only active during closing
- Input active during opening and closing
Safety edge operational testing
- Test disabled
- Test enabled for optical edges
- Test enabled for resistive rubber edges
End programming.
- Do not exit the programming menu
- Exit from the programming menu, storing the parameters set
75
MEMO
DEFAULT
DATA
CiCL
Mon
no
no
StAn
no
CFCh
no
Si
no
no
no
no