Select this parameter depending on the position (superior or inferior) of
the gate leaf in motion
SUP
inF
the gate leaf in motion is the leaf that should open first
the gate leaf in motion is the leaf that should open second
PLEASE NOTE: if installation envisages one motor only, select
Select this parameter depending on the direction of opening of gate leaf 1
AP1
Ch1
the gate leaf is opening
the gate leaf is closing
Having selected this parameter, the control unit moves the SLAVE
motor
1 If the control unit detects the SLAVE motor, the display shows
AP2
Select this parameter depending on the direction of opening of gate leaf 2
Ch2
the gate leaf is opening
the gate leaf is closing
Having selected the parameter, press OK to move to the next phase.
Er93
If the display shows
, this means the SLAVE motor is connected
incorrectly.
Check the SLAVE motor connection and repeat the initialisation
procedure
SinG
2 If the control unit does NOT detect the SLAVE motor, the display
shows
If the installation envisages only one motor, press OK to move to the
next phase.
If the installation envisages two motors, select the
Er94
press OK.
The display will show
to indicate that the SLAVE motor is not
connected, or is connected incorrectly.
Check the SLAVE motor connection and repeat the initialisation
procedure
Ft.no
3 If the control unit does not detect a photocell on the PHOTO input,
the display shows
If the installation does not envisage the use of a photocell, select
and press OK to move to the next phase.
The photocell will be automatically disabled.
Er91
If installation envisages the use of a photocell, select
OK. The display will show
connected, or is connected incorrectly.
Check the photocell connection and repeat the procedure.
4 If the control unit detects a photocell connected correctly to the
PHOTO input, it automatically switches to the working time
self-training phase.
ESC
Press OK to start the self-training phase.
Select
and press OK to exit the menu without performing the time
self-training phase.
Please note: in the case of exiting without self-training, it will not
be possible to operate the gate.
In any case, it will be possible to perform self-training in a separate
phase and program the remainder of the control unit functions, using
the specific menu.
55
doP
menu option and
Ft.Si
and press
to indicate that the photocell is not
SUP
AP2
Ft.no