Changeover from wet to dry vacuum
cleaning
ATTENTION
Please note the following when switch-
ing from wet to dry vacuum cleaning:
If you vacuum dry dust while the filter ele-
ment is still wet the filter will become ob-
structed and may be damaged beyond re-
pair.
Replace wet filter with a dry one prior to
use.
Change the filter, if required, according
to instructions under the section "Main-
tenance and Care".
Note: For permanent wet vacuum cleaning
it is advisable to use a PES flat pleated filter
(see filter systems).
Wet vacuum cleaning
DANGER
No dusts hazardous to health should be
sucked in during wet vacuuming.
Inserting the rubber lips
Illustration
Remove the brush strips.
Install the rubber lips.
Note: The structured side of the rubber lips
must point outwards.
Close the suction connection
Illustration
Properly insert the connection socket in
the suction connection.
Push in the connection socket until it
locks into place.
Remove the fleece filter bag
Illustration
Release and remove the suction head.
Pull the fleece filter bag towards the
rear.
Fold in the lock latch and tightly close
the fleece filter bag.
Dispose of the used fleece filter bag in
a dust-tight bag according to the statu-
tory provisions.
Insert and lock the suction head.
– To suck wet dirt, first remove the fleece
filter bag.
Removing the dust disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag over.
Pull the opening of the disposal bag out
toward the back over the suction support.
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove disposal bag.
Dispose of the disposal bag according
to the local provisions.
Insert and lock the suction head.
– To suck wet dirt, always remove the dis-
posal bag.
Remove the membrane filter
Illustration
Release and remove the suction head.
Remove the membrane filter.
Insert and lock the suction head.
– To vacuum wet dirt, always remove the
membrane filter (option).
General
– If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
– If the maximum liquid level is reached
the appliance will turn off automatically.
– In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
– After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Clip connection
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
– 4