Installation Instructions
Installation Instructions continued . . .
Step 3: Test eye wash unit
1. Test the eye wash station for proper operation by pulling
down the tray (see Figure 3). OPTIONAL UNIT WITH
HEATER JACKET: Test the unit by pulling the front flap
down and all the way out. This action should activate the
water spray. Check the sprayheads for proper water flow
and look for possible water leakage throughout the unit.
The eye wash station should be tested monthly to ensure
proper operation.
2. Attach the eye wash inspection tag (supplied) to the eye
wash unit. This tag is to be used for weekly inspection
documentation. Hook-and-loop fasteners are provided to
attach the tag to the unit.
3. If the eye wash unit is not working properly, remove it
from the hazard area and contact Bradley Corporation
immediately.
Bradley Corporation • 215-1271 Rev. H; EN 03-554
Figure 2b
®
On-Site
Gravity-Fed Eye Wash
Figure 3
9/11/03
S19-881
5