Bulb Replacement

CAUTION: When replacing the bulb, turn power
off and let the fixture cool.
Important: Use a clean glove or cloth when handling
the new bulb. Use isopropyl (rubbing) alcohol to clean
the bulb if it is touched with your bare hands.
1. To remove lamp shade, loosen screw 2 full turns
with a small phillips-head screwdriver. Turn shade
counterclockwise and remove.
2. To remove bulb, pull straight out of fixture.
3. To replace bulb, push bulb pins into lamp socket.
Check that the bulb is seated properly.
4. To reinstall lamp shade, place shade on fixture and
align notches on shade with tabs on fixture. Turn
clockwise. Tighten screw firmly.
SYMPTOM
POSSIBLE CAUSE
Lights will
1. Light switch is turned off.
not come
2. Light is loose or burned out.
on.
3. Fuse is blown or circuit breaker is turned
off.
4. Daylight turnoff is in effect (recheck after
dark).
5. Incorrect circuit wiring, if this is a new
installation.
6. Re-aim the sensor to cover desired area.
Lights come
1. Light control may be installed in a rela-
on in day-
tively dark location.
light.
2. Light control is in Test. (Set control switch
to an ON-TIME position).
Lights come
1. Light control may be sensing small
on for no
animals or automobile traffic (re-aim
apparent
sensor).
reason.
2. Range is set too high. (Reduce Range
setting).
3. D
B
ual
Lights turn
1. Sensor is in a relatively dark location.
off too late
(Relocate sensor, or use 3 hr or 6 hr
in Dusk-
setting).
to-Dawn
setting.
204058-01

TROUBLESHOOTING GUIDE

Timer is on.
®
rite
SPECIFICATIONS
Range . . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.(30.5
Sensing Angle . . . . . . . Up to 240°
Electrical Load . . . . . . . Up to 200 Watts Maximum
Power Requirements . . 120 VAC, 60 Hz
Operating Modes . . . . . TEST, AUTO and MANUAL
Time Delay . . . . . . . . . 1, 5, 20 minutes
D
B
Timer . . . . . 3, 6 hours, Dusk-to-Dawn
®
ual
rite
Replacement lamp . . . . T4 100W, G8 halogen bi-pin
HeathCo LLC reserves the right to discontinue prod-
ucts and to change specifications at any time without
incurring any obligation to incorporate new features in
products previously sold.
SYMPTOM
POSSIBLE CAUSE
Lights stay
1. A lamp is positioned too close to the
on continu-
sensor or pointed at nearby objects
ously.
that cause heat to trigger the sensor.
(Reposition the lamp away from the
sensor or nearby objects).
2. Light control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-painted heat-reflective surface.
(Reposition sensor. Reduce Range).
3. Light control is in Manual Mode. (Switch
to Auto).
Lights flash
1. Heat or light from the lamps may be
on and off.
turning the light control on and off.
(Reposition the lamps away from the
sensor).
2. Heat being reflected from other objects
may be affecting the sensor. (Reposi-
tion sensor).
3. Light control is in the Test mode and
warming up. (Flashing is normal under
these conditions. Turn Boost off).
Lights flash
1. Sensor is detecting its own lights.
once, then
(Reposition lamps to keep area below
stay off in
the sensor relatively dark).
Manual Mode.
5
m) with Range Boost. [varies
with surrounding tempera-
ture]
Incandescent (Up to 100 Watts
Maximum each lamp holder.)
MODE
120 VAC