Adjustments Following Ceiling Installation
The bottom edge of the plaster frame collar must be flush
to within 1/8" of bottom of the finished ceiling for proper
operation (Figure 2.). The plaster frame collar height and
rotational alignment are adjustable. The plaster frame collar
has centered alignment notches to aid in adjustments.
Collar Screw
Figure 9.
Plaster Frame Collar Height and Rotational Alignment
Height - Loosen the collar height adjustment screws and
adjust the plaster frame collar flush with the finished ceiling.
When the plaster frame collar is flush to within 1/8" of the
finished ceiling, tighten the collar adjustment screws.
Rotation - If adjustment of the rotational alignment of the
collar is necessary, loosen the collar centering thumbnut
and the collar locking thumbnut. Rotate the collar to
the desired position and then tighten the collar locking
thumbnut. It is not necessary to tighten the collar centering
thumbnut. (Figure 10.)
For PN4LED housing platforms, the two locking
N
Noee:
screws that hold the upper reflector module
(Figure 15.) must be removed prior to collar height
adjustment.

Electrical Connection

The PN4LED housing platforms feature an oversized
junction box that is divided into factory and field wiring.
(Figure 11.)
N
Noee:
DO NOT modify the factory wiring settings as it may
cause the luminaire to malfunction.
In applications using a low voltage control, a separate
compartment for low voltage wiring is provided.
Provide electrical service according the National Electrical
Code or your local electrical code from a suitable junction
box to the wiring box located on the plaster frame.
N
Noee:
The junction box will accept 1/2" metal conduit.
Review fixture labeling to make sure it is rated
for the voltage installation being used. Make sure
no bare wires are exposed outside the wire nut
connectors.
1.
Provide electrical service according to the "National
Electrical Code" or your local electrical code to the
junction box (located on the plaster frame). Supply wire
insulation must be rated for at least 90°C. The junction
box is also rated for a maximum of eight no. 12 AWG
branch circuit conductors suitable for at least 90°C.
Installation Instructions – PN4LED Recessed Housing Platforms
2.
Remove junction box cover.
3.
Remove appropriate round knockout and connect
conduit to junction box with proper connector (not
included).
4.
Connect supply wires to wires in fixture using the
linear disconnect. The linear disconnect is marked for
white (common) and black (hot) (Figure 12.). For E010,
E5LT,1ELTE, and EL3D dimming options, connect wiring
per appropriate wiring diagrams in following section.
N
Noee:
The ground wire at the junction box may need to be
secured to a ground screw.
Square Collar
Collar Centering Thumbnut
Figure 10.
Factory Wiring Compartment
Figure 11.
Ground
White
Black
Figure 12.
Collar Height Adjustment Screws
Locking Thumbscrew
Ground
White
Black
Linear Disconnect
EATON
IB520001EN
Installation instructions
Field Wiring
Compartment
Low Voltage
Compartment
To
Ballast
3