3.4 Address assignment of the solenoid coils
Depending on the linking up to 8 valve locations can be
assigned. The following applies to VABV...T2:
solenoid coil 14 occupies the lower−value address,
solenoid coil 12 occupies the higher−value address.
Addresses are assigned on the solenoid coils in ascending
order without gaps, from left to right.
The number of assigned addresses per valve location de
pends on the manifold base, irrespective of whether valves
or cover plates are fitted.
Examples of combinations of electric VABV linkings
(not all possible combinations are shown)
0
1
Valve locations/solenoid coil
a)
V1/14 V2/14 V3/14 V4/14 V5/14 V6/14 V7/14 V8/14
b)
V1/14 V2/14 V3/14 V4/14 V5/14 V6/14 V7/14 V8/14
c)
V1/14 V1/12 V2/14 V2/12 V3/14 V3/12
d)
V1/14 V1/12 V2/14 V2/12 V3/14 V3/12
a) VABV...−2T1: 2 locat. per 1 coil
b) VABV...−T1: 1 location, 1 coil
c) VABV...−2T2: 2 locations per 2 coils
d) VABV...−T2: 1 location, 2 coils
Symbol:
1)
T1: Black dot on type plate and red coil contact
2)
T2: No dot on type plate and black coil contact
Festo VTSA−ASI−...−8E8A−Z 0802NH English
Addresses
2
3
1)
(for single−solenoid 5/2−way valves)
1)
(for single−solenoid 5/2−way valves)
2)
2)
4
5
6
7
V4/14 V4/12
V4/14 V4/12
23