DANGER
Risk of injury! Set the programme se-
lector switch to "OFF" and disconnect
the mains plug prior to performing any
work on the device.
Drain and dispose of the dirt water
and the residual fresh water.
Failure
Correction
Appliance cannot be
Turn the program selection switch to the desired programme.
started
Operate the safety switch.
Insert the mains plug into the socket.
Is the indicator light voltage supply on?
Insufficient water
Check fresh water level, refill tank if necessary.
quantity
Increase the water volume on the regulating knob for water volume.
Insufficient vacuum
Clean the seals between waste water tank and cover and check for tightness, replace if required.
performance
Check the seals between waste water tank and fresh water tank for damage, replace if necessary.
Wastewater reservoir is full; shut off the appliance and empty the wastewater reservoir
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Check if the cover on the dirt water discharge hose is closed
Check the setting of the vacuum bar.
Check suction hose for blockages; clean if required.
Check the suction hose for tightness; replace if required.
Insufficient cleaning
Check the brushes for wear, replace if required.
result
Suction turbine is run-
Clean the swimmer.
ning rough
Brush does not turn
Check if foreign objects block the brush; remove foreign object if required.
Release the safety switch.
Wait for a while.
Operate the safety switch.
Vibrations during
You might need to use a softer brush.
cleaning
In case of faults that cannot be remedied using the table below please contact the customer service.
10
Faults
8
-