Accessories USING MACHINE ACCESSORIES.
• Cooling unit use instructions.
This function is used to set cooling unit start-up.
Selections are OFF – ON – AUTO, default value is OFF.
If "AUTO" is selected, when the machine is switched
on, the cooling unit starts; if the torch trigger is not
pressed after 30 seconds, it shuts off. Pressing the
torch trigger starts the unit again and it shuts off 3 mi-
nutes after releasing the trigger
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob or key
• Torch calibration
Calibration is essential when using the MIG SRS pro-
cess.
Connect the cable with the terminal to connector 5,
located on the front panel.
Connect the cable terminal to the workpiece.
Once the function is open, press the calibration key,
pick up the welding torch, remove the gas nozzle, posi-
tion the contact tip on the part to be welded and press
the button. The machine will deliver current and save
a value on the display. Repeat this operation three ti-
mes. After storing the three values, save by pressing
the SAVE
• Rules for using the push-pull torch.
Adjusting the push-pull force (ranging from -99 to
+99).
This function adjusts the drive torque of the push-
pull motor in order to make the wire feed linear.
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
Adjust the value by turning knob 2. To confirm the se-
lection press knob 2 or key
Press the DEF key to restore factory settings.
This function will be displayed on the screen only
after this accessory is assembled inside the power
supply.
.
.
• Maximum feed.
The purpose is to stop the welding machine if the wire
emerges for the preset length in cm after starting with no
passage of current. Adjustment OFF - 50 cm.
Turn knob 2 to select the parameter and confirm the
selection by pressing the knob.
To confirm the value, simply hold down the knob 2 or
the key
.
Press the DEF key to restore factory settings.
Settings
MACHINE SETTINGS MENU.
• Date and Time Setting.
Turn knob 2 to select parameter "Clock" and confirm
the selection by holding down the knob.
Adjust values by turning knob 2 and confirm by pres-
sing.
To confirm date and time press the key OK
To exit the function press the key
• Resetting factory settings.
This function resets the factory preset values.
Three resetting modes are possible:
- All.
- Resets only stored "job" working programs.
- Excludes the "jobs": Resets all but saves "Job" wor-
king programs.
Turn knob 2 to select the function and confirm the se-
lection by holding down the knob.
To confirm the value simply hold down the knob 2.
To exit the function press the key
.