7. Complete the Installation
Remove the adhesive backing from the warning label provided and apply the label to the wall of
the shower or steam enclosure.
Install the steam housing and steam head following the instructions packed with the Steam Control
Kit.
Install the steam control following the instructions packed with the Steam Control Kit.
To operate the steam control, follow the operating instructions provided with the Steam Control
Kit.
Troubleshooting
CAUTION: Risk of personal injury. Troubleshooting steps involving internal wiring or electrical
connections should be performed by a qualified electrician.
NOTE: The troubleshooting steps below only apply to the steam generator itself. For issues involving the
steam control, refer to the "Troubleshooting" section for the Steam Control Kit.
NOTE: For service parts information, visit your product page at kohler.com/serviceparts.
This troubleshooting guide is for general aid only. For service and installation issues and concerns, call
1-800-4KOHLER.
Symptoms
1.
The green LED light is
not on, and there is no
steam from the steam
head.
1230487-2-E
Probable Causes
A. No electrical power at the steam
generator.
B. Circuit breaker is in the "Off"
position.
C. Circuit breaker is not the correct
size.
D. Electrical connection in the
steam generator field service
box is loose.
14
Warning Label
Recommended Action
A1. Reset the electrical power at the
circuit breaker.
A2. Have a qualified electrician verify
that 240 V of power is present at
the steam generator.
B. Turn on the electrical power at the
breaker.
C. Verify that the circuit breaker is the
correct size. Replace the circuit
breaker if it is the wrong size.
D. Turn off all electrical power to the
steam generator. Have a qualified
electrician open the steam
generator field service box and
check/repair the connections.
Kohler Co.