GB
MT
• Connection to the mains
must be carried out by an
experienced electrician and
meet the requirements of
IEC 60364-1.
• The electrical installation
shall be according to nation-
al wiring rules.
• The device must only be con-
nected to a mains socket
via a residual-current circuit
breaker (RCD) with a rated
leakage current of not more
than 30 mA. Fuse: at least
13 ampere.
• Before each use, check the
equipment, cable and plug
for damage.
• If the power cable for this
equipment is damaged, it
must be replaced by the
manufacturer, a customer ser-
vice agent of the same or a
similarly qualiied person in
order to prevent hazards.
• Do not pull the plug from the
socket by the cable. Protect
the cable from heat, oil and
sharp edges.
• Do not carry or ix the equip-
ment by the cable.
• Use only extension cables
that are protected from spray
water and designed for out-
door use. Always fully unroll
a cable drum before use.
Check the cable for damage.
• Before any work on the
equipment, during work
breaks and in the case of
non-use, remove the plug
from the socket.
• The cross-section of the pow-
er supply cable must not be
less than 2 x 2,5 mm².
• Wear sturdy footwear to pro-
tect against electric shock.
50
• To protect against electric
shock, operate the equipment
only in an upright position.
Start-up
In keeping with current regulations a
pressure cleaner must never be oper-
ated off the drinking water mains
supply without a controllable back-
low preventer. A suitable backlow
preventer in conformity with
EN 12729 type BA must be used.
Water that has passed through a backlow
preventer is classiied as undrinkable.
A backlow preventer is available in spe-
cialist shops.
A system separator (check valve) prevents
the backlow of water and detergent into
the drinking water pipeline.
•
Employ an ordinary garden hose for
the water intake and ensure suficient
length.
•
Use the device on a domestic water
connection with an output of at least
450 l/h.
•
Irrespective of the water pipe, you can
also use the device (for example, rain
barrel) through the integrated water
suction function. This function must only
be used with a suction hose with a il-
ter basket.
The device itself must not be immer-
sed in open water sources. There
is a risk of personal injury from an
electric shock.
Do not draw in any water from na-
tural accumulations. There is a risk
of contamination from backwashed
cleaning agent.