- EN -
Intended use
ProfiLux Garden LED RGB, referred to as "unit", may only be used as specified in the following:
• Only operate the unit with OASE ProfiLux Garden LED Controller.
• For use in water fountain systems and ponds.
• For use above and under water.
• Operation under observance of the technical data.
Permissible ambient temperatures for operation
• Underwater installation: Water temperature of +4 °C to +35 °C.
• Dry installation: Air temperature of -10 °C to +40 °C.
Installation
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
• Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
• Isolate the device (disconnect from the power supply) before carrying out any work on it.
B
The device can be installed in or outside of the water.
• Fit the unit to a nozzle extension to illuminate a fountain.
• Use the supplied long Allen key for fitting if necessary.
Adjusting the tilt of the spotlight
How to proceed:
C
Slightly loosen the fastening screws on both sides of the LED spotlight.
Tilt the LED spotlight as required.
Tighten the fastening screws again.
Installation with the ground stake
How to proceed:
D, C
Fully insert the ground stake into the ground.
Fit the spotlight onto the ground stake.
Slightly loosen the fastening screws on both sides of the LED spotlight.
Tilt the LED spotlight as required.
Tighten the fastening screws again.
Wall or floor installation
How to proceed:
E, C
Drill 2 holes in a firm base or in a load bearing wall.
– Drill each 5 mm hole at least 35 mm deep.
Undo the short socket head cap screws and remove.
Remove the base plate.
Loosen the fastening screws on the spotlight head.
Tilt the spotlight head.
Fasten the LED spotlight in place.
– Use the wall plugs and screws provided.
Slightly loosen the fastening screws on both sides of the LED spotlight.
Tilt the LED spotlight as required.
Tighten the fastening screws again.
Ceiling installation
• The supplied wall plug is not approved for use in ceilings and must not be used for this purpose!
12