3.4

The solenoid valve functions as follows

The solenoid valve converts the electrical signal from the level control unit into a mechanical opening
or closing movement. The solenoid valve is closed when there is no electric current.
3.5

Intended use

Only use the product described in this manual as follows:
• For maintaining the water level of a pond by topping it up with water from the mains water supply
(drinking water).
The following restrictions apply to the unit:
• The drinking water may only enter the pond via a free flowing outlet (with air gap separation).
• Ensure that the pond has an overflow that drains the excess water into the sewer system.
• Operate in accordance with instructions. (→ Technical data)
• The solenoid valve may not be used as a safety valve.
• Only operate the unit with the provided plugs/connectors and cables.
4

Installation

4.1

Installing the solenoid valve

N O T E
• The installation of the solenoid valve described in the following may only be performed by a
trained plumber.
• Ensure that excess water (pond overflow water) can drain via a pond overflow or other
suitable protective measure into the sewer system.
How to proceed:
 D
• The drinking water supply pipe intended for connection must be thoroughly flushed out to ensure
that the function of the solenoid valve is not impaired by any residue.
• Remove the protective plugs from both ends of the solenoid valve.
• Connect the solenoid valve to the drinking water supply pipe. Ensure that the arrow on the bottom
of the valve points in the flow direction of the drinking water.
– OASE recommends: Fit the strainer in front of the solenoid valve in order to prevent the ingress
of dirt, and thus malfunctions of the solenoid valve.
– OASE recommends: Fit the solenoid valve with the solenoid pointing upward. This increases its
operating life and reduces calcium and dirt deposits.
• Fit the pipe with male thread G½ to the outlet (OUT) of the solenoid valve.
• Complete the installation with a free flowing outlet (with air gap separation).
 C
• OASE recommends: Direct the water flowing out of the free flowing outlet (9) (with air gap separa-
tion) through a DN 50 pipe (11) or larger, or via a water course into the pond.
4.2

Fitting the level control unit

All cables are permanently connected to the level control unit and cannot be disconnected.
How to proceed:
 E
1. Loosen each of the 4 screws on the transparent cover by turning 90° counter-clockwise and remove
the transparent cover (the screws remain in the cover).
2. Insert each of the four supplied screws (3.5  30 mm) into a through hole and affix the level control
unit to a suitable wall.
3. Replace the transparent cover, then push in each of the 4 screws one after another and tighten by
turning 90° clockwise.