Inbedrijfstelling - Berker 7531 40 17 Instrucciones Para El Uso

Actuador de regulación de luz ''universal'', 4 salidas, 20-210 w/va reg
Tabla de contenido
GB
Commissioning
CAUTION
Risk of irreparable damage if the prese-
lected dimming principle and the connected
load are not compatible.
Make sure before commissioning that the soft-
ware settings are compatible with the load.
Switch on the bus voltage
Allocate the physical address and load the applica-
tion software into the device.
Switch on the mains voltage at the outputs.
Switch on the mains supply
The device auto-detects the load and selects the appro-
priate dimming principle (phase cut-on or phase cut-off).
The detection phase is characterized by brief flicker-
ing of the lamp and lasts between 1 and 10 seconds
depending on power supply conditions.
Control commands received during the adaptation
procedure are executed on completion thereof.
The dimming principle can be predefined during
parameterization of the device. In this case, the
auto-detect procedure is omitted.
NL

Inbedrijfstelling

VOORZICHTIG!
Gevaar voor vernieling, wanneer het voor-
ingestelde dimprincipe en de aangesloten
last niet bij elkaar passen.
Voorafgaand aan inbedrijfstelling controle-
ren, of de software-instelling bij de last past.
Busspanning inschakelen.
Fysiek adres toewijzen en toepassingssoftware in
het toestel laden.
Netspanning op de uitgangen inschakelen.
Voedingsspanning inschakelen.
Het toestel kalibreert zich op de last en kiest het
bijpassende dimprincipe (faseaan- of -afsnijding).
Het kalibreren manifesteert zich bij ohmse lasten
door kortstondig flakkeren en duurt, afhankelijk van
de netsituatie, tussen 1-10 seconden.
Tijdens het kalibreren ontvangen bedieningscom-
mando's worden na beëindiging van de kalibrering
uitgevoerd.
Het dimprincipe kan ook via de parametrisering vast
ingesteld zijn. In dat geval vervalt het kalibreren.
33
Tabla de contenido